X1: Dc 24 V Voltage Supply - Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual

Hand-held terminal
Table of Contents

Advertisement

66/109
Bosch Rexroth AG
Pin Assignments of the IndraControl VEH 30.2
7.1.4

X1: DC 24 V Voltage Supply

WARNING
Supply the device only with voltage sources that feature protective ex‐
tra-low voltage (e.g. SELV or PELV according to EN 61131-2).
Connect only voltages and circuits to connectors, terminals and interfa‐
ces up to 50 V nominal voltage that ensure safe isolation to dangerous
voltages (e.g. by sufficient isolation and electric strength).
NOTICE
The DC 24 V power supply of the IndraControl VEH 30.2 must be fused ap‐
propriately in the final application! The max. allowed fuse is 2 A.
WARNING
The hand-held terminal must be projected correctly by the machine
manufacturer according to the risk assessment. The following safety as‐
pects must be taken into consideration:
- Correct cable length for working area limitation
- Stop pushbutton necessary and permissible
- Adequate category and performance level for the relevant application
The danger zone must be seen by the operator positioned in the ope‐
rating zone.
The device may be operated only in proper condition in adherence to
the project planning manual.
The operator must have the required qualifications and know the specifi‐
cations given in the appropriate use according to the project planning
manual.
All internally required voltages are generated with electrical isolation via a
DC/DC converter. The connection is designed as male connector strip (SL),
3.81 mm pin spacing, 2 × 4-pin, so that cables up to a maximum conductor
cross-section of 1.5 mm
2
Fig.7-4:
Pin assignment, DC 24 voltage supply X1
Parameters
Rated voltage U
N
Residual ripple at U
N
DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
Danger to life due to electric shock!
Fire hazard due to defective components!
Personal injury due to wrong project plan‐
ning!
can be connected.
Value
DC 24 V ; (+19 V to +30 V)
See
fig. 7-6 "Limit values of the DC 24 V
voltage" on page 68