08/2005
4.2.9
Displaying acknowledgement symbol of PLC alarm
Via the display machine data MD 9055: PLC_ALARM_PICTURE can be used to
activate or deactivate the following icons:
Value: -1
Value: 0
Value: 1
This functionality refers only to PLC alarms, not to PLC messages.
4.2.10
Alarm display
If several alarms are pending at the same time, only the last alarm is displayed in
the alarm and message line. If you want to display the pending NCK, PLC or HMI
alarms alternatively, you can set this in the display machine data MD 9056:
ALARM_ROTATION_CYCLE.
The following settings can be made:
< 500:
500 – 10000:
If a valid display duration is set, each alarm is displayed for this time before being
replaced by the next alarm.
Messages will not be displayed alternatively.
4.2.11
Expanding user displays from the operator interface
You can create user displays with the function "Expanding the User Interface"
(Wizard).
The exact procedure is described in submanual:
References:
4.2.12
Inch/metric switchover
The availability of the softkey, and thus the associated functionality, can be
configured using the general NCK machine data MD 10260.
In the "Machine" operating area, you can switch between the inches measuring
system and the metric measuring system via a softkey. If you want to display the
"Switch to inch" or "Switch to mm" softkey, set the machine data as follows:
MD 10260: CONVERT_SCALING_SYSTEM ≠ 0
References:
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
No icon display
Icon labeled "PLC" is displayed.
"Cancel" icon is displayed.
No change of the alarm display, only the last alarm is
displayed
Display duration of an alarm in milliseconds
/IAM/ BE1, Expanding the user interface
/FB1/ A3: Axis Monitoring, Protection Zones
/FB1/ G2: Velocities, setpoint / actual value systems, closed-loop
control
Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
IM2/4-41