Siemens SINUMERIK 840D sl Manual page 67

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Pin
Function
Assignment recommendation
no.
4
Input
Digital input $A_IN[4]
Line contactor, feedback signal
5
Ground for pins 1 ... 4
6
Ground for pins 7, 8, 10, 11
7
Output
Infeed operation (Line Module with
DRIVE-CLiQ connection)
Digital output $A_OUT[4]
8
Output
Infeed ready to start (Line Module with
DRIVE-CLiQ connection)
Digital output $A_OUT[3]
9
Ground for pins 7, 8, 10, 11
10
Output
Digital output $A_OUT[2]
Line contactor control
Input
Bero 2 – zero mark substitute
2. OFF 2
11
Output
Digital output $A_OUT[4]
Input
Probe 2 Central Measuring (check that
MD13210 = 0!)
Probe 2 - distributed measurement
(control MD13210 = 1)
12
Ground for pins 7, 8, 10, 11
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
3.6 NCU 7x0 and NX1x Terminal Assignment
BICO source/sink
CU: r0722.7
CU: p2082[3]
LM : p0860
LM :r0863.0
CU: p0742
CU: p2091.3
LM : r0899.0
CU: p0743
CU: p2091.2
CU: p2091.1
CU: p0744
LM : r0863.1
CU: r 0722.14
Drive:
p0495 = 5
Drive: p0845
CU: p2091.0
CU: p0745
CU: p0680[1] = 6
Each drive
p489 [1,2,3]=0
CU: p0680[1] = 0
Each drive
p489 [1,2,3]=6
NCU/NX Terminal Assignment
Macro number
The macro does not
perform any BICO
interconnection; the
use of the function
requires
parameterization by
the user.
1
5
1
5
1/5
The macro does not
perform any BICO
interconnection; the
use of the function
requires
parameterization by
the user.
The macro does not
perform any BICO
interconnection; the
use of the function
requires
parameterization by
the user.
1/5
The macro does not
perform any BICO
interconnection; the
use of the function
requires
parameterization by
the user.
3-11