Additional Information

8.1

Distributed Installation

8.1
For the distributed installation, an external busbar is used for the DC link connection. From
there, the cables are led to the power units. DC link rectifier adapters are used for the
connection to the power units..
Figure 8-1
Depending on the component width, two variants are available:
Component width 50/100 mm
DC link rectifier adapter with connection possibilities from 0.5 mm² to 10 mm²,
max. 36 A.
Component width 150 ... 300 mm
DC link rectifier adapter with connection possibilities from 35 mm² to 95 mm²,
max. 240 A.
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
Distributed Installation
8
8-1