The components of the SINAMICS S120 drive family and the control unit are interconnected
using DRIVE-CLiQ. When connecting the components, please note the following rules.
Rules for wiring DRIVE-CLiQ
The following rules must be observed when wiring DRIVE-CLiQ:
● Ring wiring is not permitted.
● Components must not be double-wired.
● A maximum of 8 nodes can be connected in one row. A row is always regarded as
● Up to one Line Module, 6 Motor Modules (a Double Motor Module counts as 2 nodes)
5-38
starting at the control unit.
and 3 direct measuring systems may be connected to one control unit.
Guide for the SINUMERIK 840D sl machine configuring