Siemens SIMATIC S7-1500 Manual page 95

Technology module, tm posinput 2 6es7551-1ab00-0ab0
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Parameter data record
B.1 Parameter assignment and structure of parameter data record
Table B- 1
Data record 128: Operating modes "Operating with "Counting and measurement" technology object", "Manual
operation (without technology object)"
Bit →
Bit 7
Byte
channel
0/1
0...3
0
1
2
3
4...51
52...99
4/52
4/52
Reserved
2
5/53
5/53
Interface
Reserved
standard:
0
: RS422,
B
symmetrical
1
: TTL
B
(5 V),
asymmet-
rical
94
Bit 6
Bit 5
Major Version = 0
Length of the parameter data per channel = 48
2
Bit 4
Bit 3
Header
Reserved
2
Reserved
2
Channel 0
Channel 1
Operating mode
Operating mode:
0000
: Not permitted
B
0001
: Counting / Position input
B
0010
: Measuring
B
0011 to 1111
: Not permitted
B
Basic parameters
Enable
additional
diagnostic
interrupts
Technology module TM PosInput 2 (6ES7551-1AB00-0AB0)
Bit 2
Bit 1
Minor Version = 2
Reaction to CPU STOP:
00
: Output substitute
B
value
1
01
: Keep last value
B
10
: Continue operation
B
11
: Not permitted
B
Manual, 06/2018, A5E03982218-AB
Bit 0

Hide quick links: