Sony RS-232C Interface Manual page 8

Digital powered mixer rs-232c interface
Table of Contents

Advertisement

• Fader level (2nd byte)
Set the fader level [dB].
LEVEL
-
30[H] ('0')
-70.0
31[H] ('1')
-60.0
32[H] ('2')
-55.0
33[H] ('3')
-50.0
34[H] ('4')
-45.0
35[H] ('5')
-40.0
36[H] ('6')
-35.0
37[H] ('7')
-32.5
38[H] ('8')
-30.0
39[H] ('9')
-27.5
3A[H] (':')
-25.0
3B[H] (';')
-24.0
3C[H] ('<')
-23.0
3D[H] ('=')
-22.0
3E[H] ('>')
-21.0
3F[H] ('?')
Example: When changing the sound volume of the MASTER A to 0 dB
43[H] 4C[H] 56[H] 4C[H] 40[H] 59[H] 0D[H] ('C L V L @ Y CR')
LEVEL DOWN: 43[H] 4C[H] 56[H] 2D[H] ('CLV – ')
This command is used to decrease the sound volume of the specified channel.
When this comma is sent, the sound volume keeps decreasing. When the LEVEL UP/DOWN STOP command that is described later, is sent,
the sound volume stops decreasing.
Variable range of a sound volume is from –∞ to +10 dB when the sound volume is set to the reference level 0 dB.
When the power of the SRP-X700P is turned off, the sound volume level is reset to 0 dB.
• Packet format
43[H] 4C[H] 56[H] 2D[H] "parameter" 0D[H]
• Parameter
CHANNEL
MIC1/WL1 INPUT
MIC2/WL2 INPUT
MIC3 INPUT
MIC4 INPUT
MIC5/LINE1 INPUT
MIC6/LINE2 INPUT
LINE 3 INPUT
LINE 4 INPUT
LINE OUTPUT1
LINE OUTPUT2
LINE OUTPUT3
LINE OUTPUT4
Specify the channel that you want to use, as the parameter.
Example: When decreasing the sound volume of LINE4
43[H] 4C[H] 56[H] 2D[H] 37[H] 0D[H] ('C L V - 7 CR')
LEVEL
-20.0
40[H] ('@')
-19.0
41[H] ('A')
-18.0
42[H] ('B')
-17.0
43[H] ('C')
-16.0
44[H] ('D')
-15.0
45[H] ('E')
-14.0
46[H] ('F')
-13.0
47[H] ('G')
-12.0
48[H] ('H')
-11.0
49[H] ('I')
-10.0
4A[H] ('J')
-9.0
4B[H] ('K')
-8.0
4C[H] ('L')
-7.0
4D[H] ('M')
-6.0
4E[H] ('N')
-5.0
4F[H] ('O')
CHANNEL
30[H] ( '0 ' )
LINE OUTPUT5
31[H] ( '1 ' )
LINE OUTPUT6
32[H] ( '2 ' )
LINE OUTPUT7
33[H] ( '3 ' )
LINE OUTPUT8
34[H] ( '4 ' )
MASTER A
35[H] ( '5 ' )
MASTER B
36[H] ( '6 ' )
REMOTE 1
37[H] ( '7 ' )
REMOTE 2
38[H] ( '8 ' )
REMOTE 3
39[H] ( '9 ' )
REMOTE 4
3A[H] ( ': ' )
REMOTE 5
3B[H] ( '; ' )
REMOTE 6
– 8 –
LEVEL
-4.5
50[H] ('P')
-4.0
51[H] ('Q')
-3.5
52[H] ('R')
-3.0
53[H] ('S')
-2.5
54[H] ('T')
-2.0
55[H] ('U')
-1.5
56[H] ('V')
-1.0
57[H] ('W')
-0.5
58[H] ('X')
0
59[H] ('Y')
+0.5
5A[H] ('Z')
+1.0
5B[H] ('[')
+1.5
5C[H] ('\')
+2.0
5D[H] (')')
+2.5
5E[H] ('^')
+3.0
5F[H] ('_')
3C[H] ( '< ' )
3D[H] ( '= ' )
3E[H] ( '> ' )
3F[H] ( '? ' )
40[H] ( '@ ' )
41[H] ( 'A ' )
42[H] ( 'B ' )
43[H] ( 'C ' )
44[H] ( 'D ' )
45[H] ( 'E ' )
46[H] ( 'F ' )
47[H] ( 'G ' )
LEVEL
+3.5
60[H] ('`')
+4.0
61[H] ('a')
+4.5
62[H] ('b')
+5.0
63[H] ('c')
+5.5
64[H] ('d')
+6.0
65[H] ('e')
+6.5
66[H] ('f')
+7.0
67[H] ('g')
+7.5
68[H] ('h')
+8.0
69[H] ('i')
+8.5
6A[H] ('j')
+9.0
6B[H] ('k')
+10.0
6C[H] ('l')

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srpx700p

Table of Contents