ABB ACS355 Manual page 60

Solar pump inverter (+n827)
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

60 Actual signals and parameters
All parameters
No.
Name/
Value
6124
FLOW CAL
GAIN
0.50...2.00
6131
RESET FLOW
DONE
RESET
99 START-UP DATA
9902
APPL MACRO
ABB
STANDARD
3-WIRE
ALTERNATE
MOTOR POT
HAND/AUTO
PID CONTROL
TORQUE CTRL
Description
Defines the flow calculation gain for possible
calculation correction.
Gain value
Resets the measured flow data of actual signals to
zero in
0184 TODAY FLOW
FLOW.
Flow reset is done.
Activates the flow reset.
Defines special start-up data required to set up the
inverter and allows to enter motor information.
Note: All languages are not available for printing this
manual because language list typically change as time
passes.
Selects the application macros. See Application
macros in ACS355 User's manual (3AUA0000066143
[English]).
Standard macro for solar mode.
3-wire macro for constant speed applications.
Alternate macro for start forward and start reverse
applications.
Motor potentiometer macro for digital signal speed
control applications.
Hand/Auto macro used when two control devices are
connected to the inverter:
• Device 1 communicates through the interface
defined by external control location EXT1.
• Device 2 communicates through the interface
defined by external control location EXT2.
Note: Either EXT1 or EXT2 is active at a time. The
switching between EXT1 or EXT2 happens through
digital input.
PID control for applications in which the inverter
controls a process value.
Example: For pressure controlled by the inverter
running a pressure boost pump, the measured
pressure and reference pressure are connected to the
inverter.
Torque control macro.
and
0185 CUMULA YEAR
Def/ FbEq
100 = 1
1
DONE
0
1
ABB
STANDARD
1
2
3
4
5
6
8