Fig. 2c) shows the converter efficiency for drives with quadratic load characteristic in dependency on the converter
output power P
/P
, which is in proportion to the motor power P/P
.
Out
Out-100
Rated
Fig. 2c)
Efficiency of SINAMICS S150 converters for drives with quadratic load characteristic
in dependency on the converter output power (specified in %)