Technical Data
9.1 Device technical data
For connection to approved intrinsically safe electrical circuits with:
We recommend Turck MK72-S13-EXO/24VDC solenoid drivers
Internet address www.turck.com
Certificates and approvals
Protection against explosion in accordance with EN50014, EN50020, EN50021
Intrinsic safety "i"
Identification
Permissible ambient temperature
PROFIBUS PA
PROFIBUS PA
Power supply
Bus voltage
Current consumption
Bus connection with FISCO supply unit, ia/ib group IIC or IIB with:
Bus connection with linear barrier, ia/ib group IIC with:
74
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Internal capacity C
i
Internal inductance L
i
Temperature class T4, T5
Temperature class T6
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Internal capacity Ci
Internal inductance Li
SITRANS DA400 for oscillating positive displacement pumps with protection against explosion
≤ 17.4 V
i
≤ 191 mA
i
≤ 1.35 W
≤ 33 nF
≤ 28 µH
TÜV 06 ATEX 2952
II 2(1) G EEx ia [ia] IIC T4/T5/T6
-20 °C ... +60 °C (-4 °F ... 140 °F)
-20 °C ... +50 °C (-4 °F ... 122 °F)
Clamps 91 and 92
Clamps 93 and 94
Bus-powered
9 ... 24 V
10.5 mA ± 10 %
≤ 17.5 V
i
≤ 380 mA
i
≤ 5.32 W for II B
≤ 2.52 W for II C
≤ 24 V
i
≤ 200 mA
i
≤ 1.2 W
negligible
≤ 0.8 µH
Operating Instructions, 10/2007, A5E00841127-01