Trace menu

6.5.1

Trace menu overview

Introduction
The trace menu is used to display and reset timers. The following timers are displayed in the
trace menu:
● Operating time of the device
● Times at which the alarms were activated
Elements of the digital display in the trace menu
Figure 6-11
6.5.2

Trace menu list

Timer value
Time unit
0 to 9999
SEc
0 to 60
Min
Hours.Minutes
h_M
Days.Hours
d_h
0 to 9999
SEc
0 to 60
Min
Hours.Minutes
h_M
Days.Hours
d_h
0 to 9999
SEc
0 to 60
Min
Hours.Minutes
h_M
Days.Hours
d_h
SITRANS DA400 for oscillating positive displacement pumps with protection against explosion
Operating Instructions, 10/2007, A5E00841127-01
Trace menu digital display
Timer value
Timer name
Time unit
Timer name
P1-UP
P1-T
A1-UP
A1-T
P2-UP
P2-T
Meaning
"*UP" is the time before receipt of the final alarm, in which the
associated alarm limit has been exceeded.
"*-T" is the accumulated time since the associated alarm was
received.
See remark for timer name "P1-UP"
See remark for timer name "P1-T"
See remark for timer name "P1-UP"
See remark for timer name "P1-T"
Operation
6.5 Trace menu
47