5
Adjustment > Adjustment at Time of Parts Replacement
Adjustment at Time of Parts Replacement
Inserter opening/closing adjustment (after replacing the inserter
unit)
<Pre-check>
Close the inserter and check whether the positioning pin [1] enters the frame hole in at the bottom
of the inserter.(If the pin enters the frame hole by the inserter's own weight although it does not
enter the hole smoothly, it is OK.)
If the positioning pin does not enter the hole, adjust the inserter position by adjustuing the position of
the hinge's adjusting plate following the procedure below.
<Adjustment Method>
1.Loosen two screws to remove the rear cover.
5
Adjustment > Adjustment at Time of Parts Replacement
[2]
[1]
F-5-1
F-5-1
[1]
F-5-2
F-5-2
2. Remove one screw to remove the retaining plate.
3. Remove one screw to remove the cover.
x2
4. Remove one screw to remove the retaining plate.
5-2
x1
F-5-3
F-5-3
F-5-4
F-5-4
x1
F-5-5
F-5-5
5-2

Advertisement