318
G8264 Application Guide for ENOS 8.4
For example:
RS G8264(config)# copy log tftp 192.168.1.85 // Copy logs from clients on
the master
RS G8264(config)# copy log swn 3 tftp 10.10.10.1 // Copy logs from stack
member 3
To configure up to two external hosts to log stack errors, use the command:
RS G8264(config)# logging host <host instance> {address <address> | facility
<facility> | severity <severity>
where
<host instance>
the host instance; either 1 or 2.
<address>
the IP address of the host being logged
<facility>
the facility (0‐7) of the logs being written to external syslog
servers
<severity>
the severity (0‐7) of the logs being written to external syslog
servers
To enable console output of syslog messages, use the command:
RS G8264(config)# logging console severity <severity>
where <severity> configures the severity of logs to be sent to the console.
To configure the severity of syslogs written to flash, use the command:
RS G8264(config)# logging buffer severity <severity>
where <severity> configures the severity of logs to be written to flash.