6 EDIT MENU
Function Name
Switch the transmission power from High to Low when the signal is applied to the PF [Low Power Off] input
Low Power On *1
port. This function activates only when at least one channel is configured as High Transmission Power.
to 6.2.11 TX High Power.)
Switch High/Low for the transmission power when the signal is applied to the PF [Low Power On/Off] input port.
Low Power On/Off*1
This function activates only when at least one channel is configured as High for Transmission Power.
6.2.11 TX High Power.)
It can enable the signalling Decode function when the signal is applied to the PF [Monitor Off] input port.
Monitor Off
When the signal is detected with Down Edge, you cannot switch Monitor On after this function is once enabled.
This function does not operate when the repeater enables the repeat operation.
It can disable signalling Decode when the signal is applied to the PF [Monitor On] input port.
Monitor On
When the signal is detected with Down Edge, you cannot switch Monitor Off after this function is once enabled.
Switch disable/enable signalling Decode when the signal is applied to the PF [Monitor On/Off] input port. You
Monitor On/Off
can use this function only when the signal is detected with Down Edge.
Input).)
Switch the signalling specified on the Multi-table Select to the Sub-table signalling when the signal is applied to
Multi-table Sub
the PF [Multi-table Sub] input port.
When the signal is detected with Down Edge, it cannot switch to the Main-table after the Sub-table is selected.
Switch the signalling specified on the Multi-table Select to the Main-table when the signal is applied to the PF
Multi-table Main
[Multi-table Main] input port.
When the signal is detected with Down Edge, it cannot switch to the Sub-table after the Main-table is selected.
Switch Main/Sub for the signalling specified with the Multi-table Select when the signal is applied to the PF
Multi-table Main/Sub
[Multi-table Main/Sub] input port.
Restrict QT/DQT Decode when the signal is applied to the PF [QT/DQT Decode Disable] input port.
QT/DQT Decode
When the signal is detected with Down Edge, it cannot switch the QT/DQT Decode function on after this
Disable
function is on.
This function is valid even when the repeater is performing the Repeat operation.
Activate QT/DQT Decode when the signal is applied to the PF [QT/DQT Decode Enable] input port.
QT/DQT Decode
When the signal is detected with Down Edge, it cannot switch the QT/DQT Decode function Off after this
Enable
function is on.
QT/DQT Decode
Switch disable/enable QT/DQT Decode when the signal is applied to the PF [QT/DQT Encode Disable/Enable]
Disable/Enable
input port.
Restrict QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Disable] input port.
QT/DQT
When the signal is detected with Down Edge, it cannot switch the QT/DQT Encode function On after this
Encode Disable
function is on.
Activate QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Enable] input port.
QT/DQT
When the signal is detected with Down Edge, it cannot switch the QT/DQT Encode function Off after this
Encode Enable
function is on.
QT/DQT
Switch disable/enable QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Disable/Enable]
Encode Disable/Enable
input port.
Restrict the Repeat operation when the signal is applied to the PF [Repeat Disable] input port.
Repeat Disable
It cannot configure this function if no channel is configured to the Repeat operation. When the signal is detected
with Down Edge, it cannot enable the Repeat operation after this function is enabled.
Activate the Repeat operation when the signal is applied to the PF [Repeat Enable] input port.
Repeat Enable
It cannot configure this function if no channel is configured to the Repeat operation. When the signal is detected
with Down Edge, it cannot disable the repeat operation after this function is enabled.
Switch disable/enable the repeat operation when the signal is applied to the PF [Repeat Disable/Enable] input
Repeat Disable/Enable
port. It cannot configure this function if no channel is configured to the Repeat operation.
Reset
Reset the operations and returns to the default value when the signal is applied to the PF [Reset] input port.
It can disable the Scan when the signal is applied to the PF [Scan Off] input port.
Scan Off
When the signal is detected with Down Edge, it cannot enable the Scan after this function is enabled.
It can enable the Scan when the signal is applied to the PF [Scan On] input port.
Scan On
When the signal is detected with Down Edge, it cannot disable the Scan after this function is enabled.
Scan On/Off
Switch Scan On/Off when the signal is applied to the PF [Scan On/Off] input port.
It can disable Scrambler when the signal is applied to the PF [Scrambler Off] input port.
Scrambler Off
It cannot configure this function when the optional Scrambler board is not installed.
When the signal is detected with Down Edge, it cannot switch Scrambler On after this function is enabled.
51
Description
(Refer to 6.10.1 AUX Select Tab.)
(Refer to 6.10.1 AUX Select Tab.)
(Refer to 6.10.1 AUX Select Tab.)
Field Programming Reference (FPRG)