1. Introduction
Maintenance parts stored on site (such as factory) can be reduced because different
manufacturers' devices can be used in case of a breakdown. Similar products are available
around the world due to a global standard PROFIBUS DP.

1.5.3 General Specifications

CC-Link Specifications (Ver.1.10)
Baud Rates (bps)
Connection Method
Synchronization Method
Encoding Method
Transmission Channel Type
Transmission Format
Maximum Number of Devices
Slave Station Number
Connection Cable
10
Item
156 k, 625 k, 2.5 M, 5 M, 10 M (bps)
Broadcast polling
Frame synchronization
NRZI
Bus (EIA RS485 compliant)
HDLC compliant
64 units
1 to 64
CC-Link Ver1.10 cable
(3 core twist cable with a shield)
Specification
RC620 Option Fieldbus I/O Rev.8