Procedure
Proceed as follows:
1. Select the desired interface from the selection box.
1. If you want to enable the data channel, select the "Enable Channel" check box.
2. If you want to disable the data channel, clear the "Enable Channel" check box.
3. If you want to enable automatic transfer, select the "Remote Control" check box.
4. Enter further parameters if required.
5. Confirm your entries.
Result
The data channel is programmed.
Mobile Panel 277F IWLAN
Operating Instructions, 12/2007, A5E01003940-01
Group for the data channel 2 (Channel 2)
Button for the "Network and Dial-Up Connections" dialog box
Note
"ETHERNET" is for communication via LAN and WLAN.
– Applies to "ETHERNET"
Press "Advanced" to change to "Network and Dial-Up Connections".
Open the "LAN"or "WLAN" entry. You can change the TCP/IP settings there.
Confirm your entries.
Close "Network and Dial-Up Connections".
– Applies to "USB"
No further settings are required for "USB".
The dialog closes.
Configuring the operating system
6.7 Programming the data channel
161