Fundamentals
15.3 Control- and status-word bits for NCK<->drive communication
Meaning
PLC interface for signalW
Meaning
Ramp-up function completed
M<Mx
Nact<Nmin
Nact<Nx
DC link overvoltage
Variable signaling function
Motor temperature pre-
warning
Heatsink-temperature
prewarning
Nsetp=Nact
Reserved
Power module current not
limited
Reserved
Reserved
Pulses enabled
Reserved
Reserved
264
Bit in
Remarks
ZSW2
1
15
Bit in
Remarks
signal
W
0
1
2
3
4
5
6
7
8
9
10
11
Speed controller active
12
Drive Ready
13
Only for SINAMICS
S120 with message-
frame types 101ff direct
on VDI interface
14
Only in conjunction with
positioning mode,
irrelevant for
SINUMERIK
15
Only in conjunction with
positioning mode,
irrelevant for
SINUMERIK
VDI interface (PLC)
Signal processing in the NCK
VDI interface (PLC)
Signal processing in the NCK
DB(AX).DBX94.2
Ramp-up function completed
DB(AX).DBX94.3
M<Mx
DB(AX).DBX94.4
Nact<Nmin
DB(AX).DBX94.5
Nact<Nx
DB(AX).DBX95.0
Signal not available for
SINAMICS 120!
DB(AX).DBX94.7
Signal not available for
SINAMICS 120!
DB(AX).DBX94.0
Motor temperature pre-warning
DB(AX).DBX94.1
Heatsink-temperature
prewarning
DB(AX).DBX94.6
No signal
No evaluation
DB(AX).DBX95.7
Signal not available for
SINAMICS 120!
DB(AX).DBX61.6&
DB(AX).DBX61.7
DB(AX).DBX93.5
DB(AX).DBX93.7
No signal
No evaluation
No signal
No evaluation