7SR210 Settings Guide
Description
E/F Out
Selects which inputs will switch out the E/F protection
elements.
E/F In
Selects which inputs will switch in the E/F protection elements.
SEF Out
Selects which inputs will switch out the SEF protection
elements
SEF In
Selects which inputs will switch in the SEF protection
elements
Trigger Wave Rec
Selects which inputs can trigger a waveform record
Trigger Fault Rec
Selects which inputs can trigger a fault record
Select Group 1
Switches active setting group to group 1
Select Group 2
Switches active setting group to group 2
Select Group 3
Switches active setting group to group 3
Select Group 4
Switches active setting group to group 4
Select Group 5
Switches active setting group to group 5
Select Group 6
Switches active setting group to group 6
Select Group 7
Switches active setting group to group 7
Select Group 8
Switches active setting group to group 8
Out Of Service Mode
Selects which inputs will put the relay into Out Of Service
Mode
Local Mode
Selects which inputs will put the relay into Local Mode
Unrestricted Page 38 of 61
Range
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )
Combination of ( BI1, BI2, BI3, BI4,
BI5, BI6, BI7, BI8, BI9, V1, V2, V3,
V4, V5, V6, V7, V8, V9, V10, V11,
V12, V13, V14, V15, V16 )