Example; Cable Entries - ABB ACS 601 Hardware Manual

Ac drives, 3 to 150 hp, 2.2 to 110 kw
Hide thumbs Also See for ACS 601:
Table of Contents

Advertisement

Appendix A – ACS/ACC/ACP 601 Technical Data
ACx 601 Type
ACx 601-0040-6
ACx 601-0050-6
ACx 601-0060-6
ACx 601-0070-6
ACx 601-0100-6
ACx 601-0120-6
Note: Fuses from other manufacturers can be used if they meet the ratings given in the table. Only
ultra rapid fuses guarantee the proper protection for the rectifier semiconductors. The fuses
recommended in the table are UL recognized.

Example

Cable Entries

ACx 600 Type
ACx 601-0005-3/0006-5
ACx 601-0006-3/0009-5
ACx 601-0009-3/0011-5
ACx 601-0009-6/0011-6
ACx 601-0011-3/0016-5/0016-6
ACx 601-0016-3/0020-5/0020-6
ACx 601-0020-3/0025-5/0025-6
ACx 601-0025-3/0030-5/0030-6
ACx 601-0030-3/0040-5/0040-6
ACx 601-0040-3/0050-5/0050-6
ACx 601-0050-3/0060-5
ACx 601-0060-3/0070-5/0060-6
ACx 601-0070-3/0100-5/0070-6
ACx 601-0100-3/0120-5/0100-6
ACx 601-0120-3/0140-5/0120-6
1)The terminals are 10mm (13/32") bolts for attaching ring lugs (lugs not furnished).
2)IEC version. Range of cable diameters accepted by gland plate holes. For USA version conduit plate drawings, see pages B-9 and B-10.
A-6
ACx=ACS/ACC/ACP
2
A
A
s
V
Manufacturer
50
770
660
Bussmann
63
1450
660
Bussmann
100
4650
660
Bussmann
100
4650
660
Bussmann
125
8500
660
Bussmann
200
28000
660
Bussmann
For ACS 601-0120-3, the recommended fuses for the input bridge protection are 400 A
ultrarapid fuses.
The values I
and I
for ACS 601-0120-3 are 175 A and 145 A respectively. 1.1 ·
1N
1hd
175 A = 192.5 A and 1.5 · 145 A = 217 A. Normal fuses with nominal currents higher
than 192.5 A or 217 A can be used to protect the input cable; thus, 200 A or 250 A
fuses are selected depending on the use (normal or heavy-duty, respectively).
Power and motor cable terminal sizes and tightening torques for the
ACS/ACC/ACP 601 with cable diameters accepted by the rubber
glands are given below. All power wiring must be rated for 60 °C
.
minimum
U1,V1,W1 / U2,V2,W2
Cable Ø
Maximum
mm
WIre Size
14...20
2
6mm
14...20
#10 AWG
14...20
14...20
2
10mm
14...20
#8 AWG
14...20
2
14...20
16mm
#6 AWG
14...20
2
Cu 35mm
20...26
#2 AWG
20...26
2
Al 50mm
20...26
#1 AWG
26...35
2
70mm
#00 AWG
26...35
1)
Fuses
Type
DIN 43620
170M1564
170M1565
170M1567
170M1567
170M1568
170M1570
Tightening
Torque
2)
1.5...1.8 Nm
13-18 lb.-in.
8Nm
5.9 lb.-ft.
30 Nm
22 lb.-ft.
Type
Size
Size
DIN 43653
000
170M1364
000/80
000
170M1365
000/80
000
170M1367
000/80
000
170M1367
000/80
000
170M1368
000/80
000
170M1370
000/80
Ground (PE)
Cable Ø
Maximum
WIre Size
mm
10...14
2
6mm
10...14
#10 AWG
10...14
10...14
2
10mm
10...14
#8 AWG
10...14
2
10...14
16mm
#6 AWG
10...14
10...14
10...14
2
35mm
10...14
#2 AWG
10...14
10...14
2
70mm
#00 AWG
ACS/ACC/ACP 601 Drives

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acc 601Acp 601Acs 600

Table of Contents