Ambient Conditions

ACS/ACC/ACP 600
installed for stationary use
Installation Site
Nominal output power at 0 to
Altitude
1000 m (3300') above sea
level.
Air Temperature
0 to +40 °C (32 to 104 °F)
(IP 21/22 and ACx 607 with IP
54)
0 to +25 °C (32 to 77 °F)
(ACx 601 with IP 54)
Relative Humidity
5 to 95 %
No condensation allowed. Maximum allowed relative humidity is 60 % in the presence of
corrosive gases.
Contamination
No conductive dust allowed.
Levels
Boards without coating:
(IEC 721-3-3)
Chemical gases: Class 3C2
Solid particles: Class 3S2
Boards with coating:
Chemical gases: Class 3C3
Solid particles: Class 3S2
Atmospheric
70 to 106 kPa
Pressure
0.7 to 1.05 atmospheres
Vibration
Max. 0.3 mm (0.01 in) (2 to 9
(IEC 68-2-6)
Hz), max. 1 m/s
200 Hz) sinusoidal
Shock
Not allowed
(IEC 68-2-29)
Free Fall
Not allowed
ACS/ACC/ACP 601 Drives
ACx 600 AC drives are to be used in a heated, indoor controlled
environment as specified below.
Operation
1)
2)
-40 to +70 °C
-40 to +158 °F
2)
Max. 95 %
Boards without coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
Boards with coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
70 to 106 kPa
0.7 to 1.05 atmospheres
Max. 1.5 mm (0.06 in) (2 to 9
2
2
(3.3 ft/s
)(9 to
Hz), max. 5 m/s
(9 to 200 Hz) sinusoidal
Max. 100 m/s
(330 ft/s
250 mm (10in) (weight under
100 kg) (220 lbs)
100 mm (4 in)(weight over 100
kg) (220 lbs)
1)
At sites over 1000 m (3300 ft) above sea level, the maximum output current is
derated 1 % for every additional 100 m (330 ft). If the installation site is higher than
2000 m (6600 ft) above sea level, please contact your local ABB distributor or office for
further information.
2)
See subsection Output Current Temperature Derating , page A-3.
Appendix A – ACS/ACC/ACP 601 Technical Data
Storage
in the protective package
-
2
2
(16.4 ft/s
)
2
, 11 ms
2
)
ACx=ACS/ACC/ACP
Transportation
in the protective package
-
-40 to +70 °C
-40 to +158 °F
Max. 95 %
Boards without coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
Boards with coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
60 to 106 kPa
0.6 to 1.05 atmospheres
Max. 3.5 mm (0.14 in) (2 to 9
2
2
Hz), max. 15 m/s
49.2 ft/s
)
(9 to 200 Hz) sinusoidal
2
Max. 100 m/s
, 11 ms
2
(330 ft/s
)
250 mm (10in) (weight under
100 kg) (220 lbs)
100 mm (4 in)(weight over 100
kg) (220 lbs)
A-13