FLEXANALOG ITEMS
Address
FlexAnalog name
6760
SRC 2 V_1 Angle
A
6761
SRC 2 V_2 Mag
6763
SRC 2 V_2 Angle
7168
SRC 1 P
7170
SRC 1 Pa
7172
SRC 1 Pb
7174
SRC 1 Pc
7176
SRC 1 Q
7178
SRC 1 Qa
7180
SRC 1 Qb
7182
SRC 1 Qc
7184
SRC 1 S
7186
SRC 1 Sa
7188
SRC 1 Sb
7190
SRC 1 Sc
7192
SRC 1 PF
7193
SRC 1 Phase A PF
7194
SRC 1 Phase B PF
7195
SRC 1 Phase C PF
7200
SRC 2 P
7202
SRC 2 Pa
7204
SRC 2 Pb
7206
SRC 2 Pc
7208
SRC 2 Q
7210
SRC 2 Qa
7212
SRC 2 Qb
7214
SRC 2 Qc
7216
SRC 2 S
7218
SRC 2 Sa
7220
SRC 2 Sb
7222
SRC 2 Sc
7224
SRC 2 PF
7225
SRC 2 Phase A PF
7226
SRC 2 Phase B PF
7227
SRC 2 Phase C PF
7552
SRC 1 Frequency
7554
SRC 2 Frequency
9024
Prefault Ia Mag [1]
9026
Prefault Ia Ang [1]
9027
Prefault Ib Mag [1]
9029
Prefault Ib Ang [1]
9030
Prefault Ic Mag [1]
9032
Prefault Ic Ang [1]
9033
Prefault Va Mag [1]
9035
Prefault Va Ang [1]
9036
Prefault Vb Mag [1]
9038
Prefault Vb Ang [1]
A-4
Units
Description
Degrees
Source 2 positive-sequence voltage angle
Volts
Source 2 negative-sequence voltage magnitude
Degrees
Source 2 negative-sequence voltage angle
Watts
Source 1 three-phase real power
Watts
Source 1 phase A real power
Watts
Source 1 phase B real power
Watts
Source 1 phase C real power
Vars
Source 1 three-phase reactive power
Vars
Source 1 phase A reactive power
Vars
Source 1 phase B reactive power
Vars
Source 1 phase C reactive power
VA
Source 1 three-phase apparent power
VA
Source 1 phase A apparent power
VA
Source 1 phase B apparent power
VA
Source 1 phase C apparent power
---
Source 1 three-phase power factor
---
Source 1 phase A power factor
---
Source 1 phase B power factor
---
Source 1 phase C power factor
Watts
Source 2 three-phase real power
Watts
Source 2 phase A real power
Watts
Source 2 phase B real power
Watts
Source 2 phase C real power
Vars
Source 2 three-phase reactive power
Vars
Source 2 phase A reactive power
Vars
Source 2 phase B reactive power
Vars
Source 2 phase C reactive power
VA
Source 2 three-phase apparent power
VA
Source 2 phase A apparent power
VA
Source 2 phase B apparent power
VA
Source 2 phase C apparent power
---
Source 2 three-phase power factor
---
Source 2 phase A power factor
---
Source 2 phase B power factor
---
Source 2 phase C power factor
Hz
Source 1 frequency
Hz
Source 2 frequency
Amps
Fault 1 pre-fault phase A current magnitude
Degrees
Fault 1 pre-fault phase A current angle
Amps
Fault 1 pre-fault phase B current magnitude
Degrees
Fault 1 pre-fault phase B current angle
Amps
Fault 1 pre-fault phase C current magnitude
Degrees
Fault 1 pre-fault phase C current angle
Volts
Fault 1 pre-fault phase A voltage magnitude
Degrees
Fault 1 pre-fault phase A voltage angle
Volts
Fault 1 pre-fault phase B voltage magnitude
Degrees
Fault 1 pre-fault phase B voltage angle
D30 LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL