Dr 47 - Mmc-Id - Siemens SIWAREX FTA Device Manual

Weighing electronics for automatic scale
Table of Contents

Advertisement

Name
Type
Log ID
DINT
Log data 1
STRING[40]
Log data 2
STRING[40]
Log data 3
STRING[40]
Log data 4
STRING[40]
Table 5-32
Allocation of DR 47

5.29.1 DR 47 - MMC-ID

Identification of the MMC card.
5.29.2 DR 47 - Log ID
The log ID is a unique log number that can be used to identify the log. The number
is incremented with every logging procedure.
5.29.3 DR 47 - Last log data
The output log consists of 4 strings.
5.30 DR 120/121 Trace - Data logging
Measurement values and actual states in the weighing process can be stored in
RAM memory of the SIWAREX FTA or in the MMC card with the trace function.
When recording to RAM, SIWATOOL FTA reads the trace elements through data
record 120, when recording to MMC through data record 121.
The recording can be started with the "Start Recording" command
with "End recording" command 71.
By defining parameters in data record DR 7
be defined. The data record cannot be read through the SIMATIC CPU.
Name
Element ID MMC-Trace
Length
Trace element
Block check character
Crc
Table 5-33
Trace data record
SIWAREX FTA
Address
Default
DBD008
DBB012
STRING[40] = 0H
DBB054
STRING[40] = 0H
DBB096
STRING[40] = 0H
DBB0138
STRING[40] = 0H
180
Type
Length
Default
DWORD
4
WORD
2
BYTE[n]
64
WORD
2
72
Range of Values / Meaning
0
ID for stored log text
Log text Part 1
Log text Part 2
Log text Part 3
Log text Part 4
MMC Parameter
Range of Values / Meaning
0
Seq. Number of the stored trace element
0
Number of valid data bytes;
If 0, then the requested element number does
not exist
0
Trace data
0
CRC16 (seq.No. + Trace element)
Weighing Functions
Reference
70
and stopped
the trace function can
5-123