en | Operation with ICON LCD Codepad
4 Sensor Watch Fault
A sensor watch fault registers because one or more detection devices failed to detect any
movement during the disarmed state for the time period programmed by your installer. The
fault clears once the zone in question detects movement and resets. Press the [4] key until
two beeps sound. This displays the zone reporting the sensor watch fault.
5 RF Sensor Missing
An RF sensor missing fault registers because one or more RF detection devices fails to
communicate to the RF radio receiver for the time period programmed by your installer. The
fault clears once the RF device in question successfully transmits to the RF radio receiver.
Press the [5] key until two beeps sound. This displays the RF detection device reporting the
RF sensor watch fault.
6 Communication Fail
A communication fail registers when the control panel fails to communicate with the receiving
party (such as a monitoring company, mobile phone). The communication fault clears once the
control panel successfully reports to the receiving party.
A communication fail also registers when network module is disconnected or tampered.
To determine which receiver or module failed to communicate, press the [6] key.
7 Output and Codepad Fail
The output fault registers when the output expander B308 is disconnected or tampered.
The codepad fault registers when any codepad is tampered or disconnected from the control
panel.
To determine which fault occurred, press the [7] key.
8 Keyfob Low Battery
This fault occurs when any of the RF keyfobs report a low battery condition to the control
panel. To determine which keyfob failed, press the [8] key. Only keyfob 1 to 16 faults display
on the codepad through zone indicator 1 to 16.
See also
5.8

Date and Time

Programming the date and time is only required when you need functions such as automatic
test reports, automatic arming, and history events to operate correctly.
How to Program the Date and Time
1.
2.
3.
5.9
Turning Outputs On/Off
This feature is only applicable if your installer set up an output that can be turned on or off by
the codepad or A-Link Plus. The output programmed by your installer can control a pool pump
or outside lighting. Up to 20 separate outputs can be programmed.
2017.09 | 04 | F.01U.298.028
Date and Time, page 20
Enter your Master Code, followed by [6] and the [#] key (for example, [25806#]). Three
beeps sound, and the STAY and AWAY indicators flash.
Enter the day, month, year, hour, and minute(DD, MM, YY, HH, MM format) (for example,
DD = day of the month, MM = month of the year, YY = current year, HH = hour of the day,
MM = minute of the day). To program the hour of the day, use the 24:00 hour format.
Press the [#] button to exit and return to the disarmed state. Two beeps sound, and the
STAY and AWAY indicators turn off. If a long beep sounds, an error was made when
entering the date and time.