en | Operation with ICON LCD Codepad
5

Operation with ICON LCD Codepad

5.1
Arming the System
There are several ways to arm the system depending on whether you are:
If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and
constantly displayed on the remote codepad. The zone becomes an active part of the system
when the zone is restored.
For example, if a window is left open after Exit Time expired, the window is not an active part
of the system until the window is closed. Opening the window after Exit Time expired causes
an alarm condition.
Below table defines the different methods for arming the system.
Mode
AWAY Mode
STAY Mode 1
STAY Mode 2
Tab. 5.4: Arming Methods
5.1.1
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. If the
system does not arm and a long beep is heard, forced arming is not permitted. If this is the
case, you must ensure that all zones are sealed or manually isolated before you can arm the
system.
Refer to Isolating Zones, page 17.
5.1.2
Arming in AWAY Mode
When you leave your premises and require all zones to be in a ready state to detect intrusion,
arm the system in AWAY Mode.
There are two different methods for arming the system in AWAY Mode. Method one is
standard and always operates. Method two is optional and can be disabled by your installer if
you do not want to use single button arming.
Method One
Method Two
Tab. 5.5: How to Arm the System in AWAY Mode
2017.09 | 04 | F.01U.298.028
Leaving the premises and require all active zones to be in a ready state for an intruder.
Remaining in the premises and only require part of the system to be in a ready state for
and intruder.
Arming Method
Arms the entire system. Refer to Arming in AWAY Mode, page 12.
Arms all zones except those programmed to be automatically isolated
by the installer. Refer to Arming in STAY Mode 1, page 13.
Arms all zones except those programmed to be automatically isolated
by the Master Code holder. Refer to Arming in STAY Mode 2, page 13.
Enter your user code followed by the [#] button (for example,
[2580#]).
Two beeps sound and the AWAY indicator displays. Exit Time
starts counting.
Hold down the [#] button until two beeps sound.
The AWAY indicator displays and Exit Time starts counting.
User's Guide