Installation wizard
Attribute
IF Cable
IF Cable Length
Modem
Short Power Cycle For
Recovery
NOTE
5-94
Enter the total length of the IF cable from the ODU to the
CMU in metres or feet as appropriate. The maximum
permitted length is 190 metres (620 ft) for standard IF
cable.
The units can be changed using the Properties web page.
If set to 'Enabled', a short power cycle will cause the
CMU to boot in recovery mode.
If set to 'Disabled', the CMU will boot in recovery mode
only through use of the front panel recovery switch.
If it is reasonably easy to access the CMU to press the
Recovery button then set to 'Disabled'. Set to 'Enabled'
only if the CMU will be installed in a location that is
difficult to access. The short power cycle provides an
additional way to start the CMU in recovery mode for
remote operation.
For more information, see
7-12.
Ensure that Link name is the same at both ends of the link. If the Link
name is not the same, the link will not establish.
NOTE
If the required IF cable length is between 190 and
300 meters (620 ft and 980 ft), contact Technical
Support.
Chapter 5 Installation
Meaning
Recovering the CMU
phn-1478_005v000
on page
Apr 2010