Maintenance
Periodic checks must be carried out by Miele Technical Service after
1000 operating hours or every 18 months at the latest.
Maintenance covers the following:
– Electrical safety according to national regulations
– Door mechanism and door seal
– Any screw connections and connectors in the wash cabinet
– Water inlet and drainage
– Internal and external dispensing systems
– Spray arms
– Filter combination
– Sump including drain pump and non-return valve
– All mobile units, baskets, modules and inserts
– Steam condenser
– Wash pressure sensor
If there is a communication module:
– Connected printer
– Network connection
External documentation software and the computer network will
not be tested by Miele.
The following operational tests will be carried out within the
framework of the maintenance:
– A program will be run as a test run
– Seals will be tested for water tightness
– All relevant measuring systems will be safety tested, including fault
displays
– Safety features
Maintenance measures