Toshiba TOSVERT VF-AS3 Instruction Manual page 533

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Communication
Title
Parameter name
No.
Shock monitoring
F592
0592
detection
Shock monitoring
F593
0593
detection level
Shock monitoring
F595
0595
detection time
Shock monitoring
F596
0596
detection hysteresis
Shock monitoring
F597
0597
detection wait time
Shock monitoring
F598
0598
detection condition
Parameter for
F600
0600
manufacturer
Stall prevention
F601
0601
level 1
F602
0602
Trip record retention
Emergency off stop
F603
0603
pattern
Emergency DC
F604
0604
braking time
Output phase loss
F605
0605
detection
Motor overload
F606
0606
reduction frequency
threshold
F607
0607
Motor overload time 10 - 2400
F608
0608
Input phase loss trip
Adjustment range
Unit
0: Overcurrent/
Overtorque detection
1: Undercurrent/
-
Undertorque
detection
0 - 250
%
0.0 - 10.0
s
0 - 100
%
0.0 - 300.0
s
0: During run
1: During run (except
-
Acc/Dec)
-
-
10 - 200 (HD)
%
10 - 160 (ND)
0: Clear at power off
-
1: Retain at power off
0: Trip
1: Trip after Deceleration
stop
2: Trip after Emergency
DC braking
3: Trip after deceleration
-
stop by F515
4: Trip after Quick
deceleration stop
5: Trip after Dynamic
quick deceleration
stop
0.0 - 20.0
s
0: Disabled
1: At startup (only one
time after power on)
2: At every startup
3: During run
-
4: At every startup +
during run
5: Output shut off
detection
0.0 - 60.0
Hz
s
0: Disabled
-
1: Enabled
11-31
Minimum
Write
setting unit
Default
during
(Panel/
setting
running
Communication)
*6
-
0
Y
150
Y
0.5
Y
10
Y
0.0
Y
-
0
Y
-
-
-
150 (HD)
Y
120 (ND)
-
0
Y
-
0
N
1.0
Y
-
0
N
6.0
Y
300
Y
-
1
N
11. Table of parameters
E6582062
User
Reference
setting
1
[6. 29]
3
-
[6. 24. 3]
[6. 30. 2]
[6. 30. 3]
9
[6. 30. 4]
10
11
[6. 30. 5]
[5. 2. 5]
[6. 30. 1]
[6. 30. 6]