For the ND rating
• 200 V class (220 V input power supply, without a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
screw
FR-A820-[]
size
00046(0.4K) to
M4
00167(2.2K)
00250(3.7K)
M4
00340(5.5K)
M5 (M4)
00490(7.5K)
M5 (M4)
00630(11K)
M5
00770(15K)
M6
00930(18.5K)
M8(M6)
01250(22K)
M8(M6)
01540(30K)
M8(M6)
01870(37K)
M10(M8)
02330(45K)
M10(M8)
03160(55K)
M12 (M8) 24.5
• 200 V class (220 V input power supply, with a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
screw
FR-A820-[]
size
00046(0.4K) to
M4
00167(2.2K)
00250(3.7K)
M4
00340(5.5K)
M5 (M4)
00490(7.5K)
M5 (M4)
00630(11K)
M5
00770(15K)
M6
00930(18.5K)
M8(M6)
01250(22K)
M8(M6)
01540(30K)
M8(M6)
01870(37K)
M10(M8)
02330(45K)
M10(M8)
03160(55K)
M12 (M8) 24.5
03800(75K)
M12 (M8) 24.5
04750(90K)
M12 (M8) 24.5
• 400 V class (440 V input power supply, without a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
screw
*4
FR-A840-[]
size
00023(0.4K)
to
M4
00126(3.7K)
00170(5.5K)
M4
00250(7.5K)
M4
00310(11K)
M5
00380(15K)
M5
00470(18.5K)
M6
00620(22K)
M6
00770(30K)
M6
00930(37K)
M8
01160(45K)
M8
01800(55K)
M8
58
2. INSTALLATION AND WIRING
2.5 Main circuit terminals
Crimp terminal
Tightening
torque
R/L1,
*4
N·m
S/L2,
U, V, W
T/L3
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
14-5
8-5
2.5
14-5
14-5
4.4
22-6
22-6
7.8
38-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
14.7
80-10
60-10
14.7
100-10 100-10 100
100-12 100-12 100
Crimp terminal
Tightening
Torque
R/L1,
*4
N·m
S/L2,
U, V, W
T/L3
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
14-5
8-5
2.5
14-5
14-5
4.4
22-6
22-6
7.8
22-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
14.7
60-10
60-10
14.7
100-10 100-10 100
100-12 100-12 100
150-12 150-12 125
150-12 150-12 150
Crimp terminal
Tightening
Torque
R/L1,
N·m
S/L2,
U, V, W
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
8-5
5.5-5
4.4
14-6
8-6
4.4
14-6
14-6
4.4
22-6
22-6
7.8
22-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
P/+,
S/L2,
(grounding)
W
P1
T/L3
cable
2
2
2
2
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
14
8
14
5.5
14
14
14
8
22
22
22
14
38
22
38
14
38
38
38
22
60
60
60
22
80
60
80
22
100
100
38
100
100
38
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
S/L2,
P/+, P1
(grounding)
W
T/L3
cable
2
2
2
2
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
14
8
14
5.5
14
14
14
8
22
22
22
14
22
22
38
14
38
38
38
22
60
60
60
22
60
60
80
22
100
100
38
100
125
38
125
150
38
150
2×100 60
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
P/+,
S/L2,
(grounding)
W
P1
T/L3
cable
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
8
5.5
8
5.5
14
8
14
8
14
14
22
14
22
22
22
14
22
22
22
14
38
38
38
22
60
60
60
22
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
T/L3
T/L3
14
14
2.5
2.5
12
12
4
4
10
10
6
6
6
8
16
10
6
6
16
16
4
4
25
25
2
4
35
25
2
2
35
35
1/0
1/0
50
50
3/0
1/0
70
70
4/0
4/0
95
95
4/0
4/0
95
95
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
T/L3
T/L3
14
14
2.5
2.5
12
12
4
4
10
10
6
6
8
8
10
10
6
6
16
16
4
4
25
25
4
4
25
25
2
2
35
35
1/0
1/0
50
50
1/0
1/0
70
70
4/0
4/0
95
95
4/0
4/0
95
95
250
250
—
—
300
300
—
—
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
T/L3
T/L3
14
14
2.5
2.5
12
14
2.5
2.5
12
12
4
4
10
10
6
6
8
10
10
6
6
8
16
10
6
6
16
16
4
4
25
25
4
4
25
25
1
2
50
50
1/0
1/0
50
50
2
*3
)
Earthing
(grounding)
W
cable
2.5
4
6
16
16
16
25
25
25
35
50
50
2
*3
)
Earthing
(grounding)
W
cable
2.5
4
6
10
16
16
16
25
25
35
50
50
—
—
2
*3
)
Earthing
(grounding)
W
cable
2.5
4
4
10
10
16
16
16
16
25
25