Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 240

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

• Functions of terminals 1 and 4 by control (— : no function)
*1
Pr.858 setting
0
Speed command (AU signal-ON)
(initial value)
Magnetic flux command
*3
*4
1
Magnetic flux command
Torque limit (Pr.810 = 1)
Power driving torque limit (Pr.810 =1)
Torque limit (Pr.810 = 1)
*2
4
*3
Torque limit (Pr.810 = 1)
9999
*1
When Pr.868 ≠ "0", the other functions of terminal 1 (auxiliary input, override function, PID control) do not operate.
*2
When Pr.858 ≠ "0", PID control and speed commands using terminal 4 do not operate even when the AU signal is ON.
*3
When both Pr.858 and Pr.868 are "1" (magnetic flux command) or "4" (torque limit), the function of terminal 1 has higher priority, and terminal 4
does not function.
*4
Valid when Vector control compatible options are installed and the Vector control is selected.
 Torque limit level through the CC-Link/CC-Link IE Field Network
communication (Pr.810 = "2", Pr.805, Pr.806)
• When the CC-Link (FR-A8NC) or CC-Link IE Field network (FR-A8NCE/FR-A800-GF) communication is used, the Pr.805
or Pr.806 setting is used as the torque limit value. (Internal torque limit 2)
• When the CC-Link communication (ver. 2) is used in the quadruple or octuple setting (Pr.544 = "14, 18, 114, or 118"), the
torque limit value can be input using a remote register (RWwC).
• When the CC-Link IE Field Network is used, the torque limit value can be input using a remote register (RWw2).
Pr.804
setting
CC-Link/PLC function
1
Torque limit by Pr.805, Pr.806
Torque limit by remote register
3
*3
(RWw2)
Torque limit by remote register
5
*3
(RWw2)
6
Torque limit by Pr.805, Pr.806
*1
The torque limit setting is defined as an absolute value.
*2
Can also be set from operation panel or parameter unit.
*3
The torque can also be limited by setting a value in Pr.805 or Pr.806.
*4
If set by operation panel or parameter unit, setting range is "673 to 1327 (-327% to 327%)", setting increment is 1%.
Terminal 4 function
0 (initial value)
1
2
3
4
5
6
9999
*4
0 (initial value)
1
2
3
4
*4
5
6
9999
0 (initial value)
1
2
3
4
5
6
9999
Torque limit input
CC-Link IE
*2
Torque limit by remote register
*3
(RWw2)
Torque limit by remote register
*3
(RWw2)
*2
5.3 Speed control under Real sensorless vector control, vector control, PM sensorless vector control
*2
Pr.868 setting
Speed setting assistance
*4
Magnetic flux command
Torque limit (Pr.810 = 1)
Torque bias (Pr.840 = 1 to 3)
Speed setting assistance
*4
Magnetic flux command
Torque limit (Pr.810 = 1)
Torque bias (Pr.840 = 1 to 3)
Speed setting assistance
*4
Magnetic flux command
Regenerative torque limit (Pr.810=1)
Torque limit (Pr.810 = 1)
Torque bias (Pr.840=1 to 3)
Setting range
600 to 1400
(-400% to 400%)
-32768 to 32767 (two's
complement)
(-327.68% to 327.67%)
Terminal 1 function
*4
*4
*4
Setting
*1
increments
1%
*4
0.01%
*4
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
239