Siemens SINUMERIK 840Di Manual page 278

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

10 NC Start-Up with HMI Advanced
10.2 Machine and setting data
Default
passwords
Redefining
protection levels
Data areas
Table 10-4
Protection levels: Machine data
Number
MMC machine data ($MM_....)
9200
USER_CLASS_READ_TOA
9201
USER_CLASS_WRITE_TOA_GEO
9202
USER_CLASS_WRITE_TOA_WEAR
9203
USER_CLASS_WRITE_FINE
9204
USER_CLASS_WRITE_TOA_SC
9205
USER_CLASS_WRITE_TOA_EC
9206
USER_CLASS_WRITE_TOA_SUPVIS
9207
USER_CLASS_WRITE_TOA_ASSDNO
9208
USER_CLASS_WRITE_MAG_WGROUP
9209
USER_CLASS_WRITE_TOA_ADAPT
9210
USER_CLASS_WRITE_ZOA
9213
USER_CLASS_OVERSTORE_HIGH
9214
USER_CLASS_WRITE_PRG_CONDIT
9215
USER_CLASS_WRITE_SEA
9218
USER_CLASS_SELECT_PROGRAM
9219
USER_CLASS_TEACH_IN
9220
USER_CLASS_PRESET
9221
USER_CLASS_CLEAR_RP A
9222
USER_CLASS_WRITE_RP A
9231
USER_CLASS_WRITE_RP A_1
9232
USER_BEGIN_WRITE_RPA_1
9233
USER_END_WRITE_RPA_1
9234
USER_CLASS_WRITE_RP A_2
10-278
The following default passwords are defined for the protection levels 1 though 3:
Protection level 1
SUNRISE
Protection level 2
EVENING
Protection level 3
CUSTOMER
Notice
A system power-up with loading the default machine data (after "Delete NCK
data", e.g. using 840Di Start-up) will reset the passwords to the default values.
In order to provide safe access protection, the default passwords should be
modified.
The protection levels of machine and/or setting data can be modified both with
respect to complete machine or setting data ranges and for single data.
Identifier
Protection level "Read tool offsets"
Protection level "Write tool geometry"
Protection level "Write tool wear data"
Protection level "Write fine"
Protection level "Change additive tool offsets"
Protection level "Change tool setup offsets"
Protection level "Change tool monitoring limit
values"
Change assigned D-No. of a tool edge
Change wear group magazine location/mag.
Protection level "Tool adapter data"
Protection level "Write settable zero offset"
Protection level "Extended overstore"
Protection level "Program control"
Protection level "Write setting data"
Protection level "Program selection"
Protection level "TEACH IN"
Protection level "PRESET"
Protection level "Delete R parameters"
Protection level "Write R parameters"
Protection level for the first RPA area
Start of the first RPA area
End of the first RPA area
Protection level for the second RPA area
Name
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
06.03
Ref.

Advertisement

Table of Contents
loading

Table of Contents