9.3.2
Communication detail settings
Make the settings according to the usage environment.
Item
Description
Set this item when change the
transmission speed used for
Transmission
communication with the connected
Speed
equipment.
(Default: 9600bps)
Set this item when change the
data length used for
Data Bit
communication with the connected
equipment.
(Default: 8bits)
Specify the stop bit length for
Stop Bit
communications.
(Default: 1bit)
Specify whether or not to perform
a parity check, and how it is
Parity
performed during communication.
(Default: Even)
9 - 4
9. BAR CODE READER CONNECTION
9.3 GOT Side Settings
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
Range
4800bps,
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
7bits/8bits
1bit/2bits
None
Even
Odd
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
User's Manual of GOT used.
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.