GE C60 Instruction Manual page 245

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 17 of 29)
ADDR
REGISTER NAME
7690
...Repeated for module number 22
76A0
...Repeated for module number 23
76B0
...Repeated for module number 24
76C0
...Repeated for module number 25
76D0
...Repeated for module number 26
76E0
...Repeated for module number 27
76F0
...Repeated for module number 28
7700
...Repeated for module number 29
7710
...Repeated for module number 30
7720
...Repeated for module number 31
7730
...Repeated for module number 32
7740
...Repeated for module number 33
7750
...Repeated for module number 34
7760
...Repeated for module number 35
7770
...Repeated for module number 36
7780
...Repeated for module number 37
7790
...Repeated for module number 38
77A0
...Repeated for module number 39
77B0
...Repeated for module number 40
77C0
...Repeated for module number 41
77D0
...Repeated for module number 42
77E0
...Repeated for module number 43
77F0
...Repeated for module number 44
7800
...Repeated for module number 45
7810
...Repeated for module number 46
7820
...Repeated for module number 47
7830
...Repeated for module number 48
Ohm Inputs (Read/Write Setting) (2 modules)
7840
Ohm Inputs x Function
7841
Ohm Inputs x ID
7847
Ohm Inputs x Reserved (9 items)
7850
...Repeated for module number 2
Frequency (Read Only)
8000
Tracking Frequency
FlexState Settings (Read/Write Setting)
8800
FlexState Parameters (256 items)
FlexElement (Read/Write Setting) (16 modules)
9000
FlexElement Function
9001
FlexElement Name
9004
FlexElement InputP
9005
FlexElement InputM
9006
FlexElement Compare
9007
FlexElement Input
9008
FlexElement Direction
9009
FlexElement Hysteresis
900A
FlexElement Pickup
900C
FlexElement DeltaT Units
900D
FlexElement DeltaT
900F
FlexElement Pkp Delay
9010
FlexElement Rst Delay
9011
FlexElement Block
9012
FlexElement Target
9013
FlexElement Events
9014
...Repeated for module number 2
GE Multilin
RANGE
0 to 1
---
0 to 65535
2 to 90
---
0 to 1
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0.1 to 50
-90 to 90
0 to 2
20 to 86400
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
C60 Breaker Management Relay
B.3 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
F205
---
1
F001
Hz
0.01
F001
---
---
F300
---
1
F102
---
---
F206
---
1
F600
---
1
F600
---
1
F516
---
1
F515
---
1
F517
%
0.1
F001
pu
0.001
F004
---
1
F518
---
1
F003
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
DEFAULT
B
0 (Disabled)
"Ohm Ip 1 "
0
0
0
0 (Disabled)
"FxE \x040"
0
0
0 (LEVEL)
0 (SIGNED)
0 (OVER)
30
1000
0 (Milliseconds)
20
0
0
0
0 (Self-reset)
0 (Disabled)
B-25