Toshiba strata CT Installation & Maintenance Manual page 88

Digital business telephone system
Hide thumbs Also See for strata CT:
Table of Contents

Advertisement

Strata CT Installation
Remote Cabinet Data Cables and Connectors
Table 2-15
Data Cables
BDCL1A-MS1
BDCL1A-M2
BDCL1A-S2
X=applies to connector
8.
H
9.
10. Run Command Program 91-1 Automatic PCB Recognition and Port Renumber.
C
The RRCU PCB and its controls and connectors are shown in
Figure 2-34
Remote Expansion Cabinet Printed Circuit Board (RRCU1A)
2-52
M1
Connect the fiber optic cables
N
Pass the fiber optic cable through the protective tube.
N
Route the tube through the clamp attached to the inner cabinet wall and secure the
clamp
N
Attach fiber to the SC connectors on the ROMS1A daughterboard.
N
The TX side of the Master connects to the RX side of the slave.
N
The RX side of the Master connects to the TX side of the slave.
N
TAIS recommends that the cables be marked within the cabinet for ease of
maintenance.
N
Observe the minimum bend radius of 30mm.
Restore power.
Master 1
Connect to
Base Cabinet
Slave 1
Connect
to MSBU
Master 2
Connect to
Base Cabinet
Slave 2
Connect
to MSBU
RS-232
Port
RRCU Connectors
S1
X
X
ROMS1A
P3
P4
RRCU1A
M2
X
Figure 2-34
and
Table
Strata CT I&M Manual October 2000
S2
X
2-16.

Advertisement