11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings

Extension No Answer Redirection Time

Specifies the length of time that a call queues at an extension before it is redirected to the next member
extension of the incoming call distribution group, in UCD or Priority Hunting distribution method.
Default
None
Value Range
None, 10 ´ n (n=1–15) s
Maintenance Console Location
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
Feature Manual References
10.1.2 ICD Group Features—Group Call Distribution
10.1.6 ICD Group Features—Queuing
No. of Unanswered Calls for Automatic Log-out
Specifies the number of consecutive unanswered calls before a member extension is automatically logged out
from the incoming call distribution group.
Default
None
Value Range
None, 1–15
Maintenance Console Location
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
Feature Manual References
10.1.3 ICD Group Features—Log-in/Log-out
Maximum No. of Busy Extension
Specifies the number of extensions that can accept calls simultaneously in the incoming call distribution group.
Default
Max.
Value Range
Max.: Call arrives at an idle extension.
1–32: Call will not arrive at an idle extension when the number of busy extensions exceeds the assigned
number.