For internal use only
Table 2-3
8-pin Western socket
Note
Direct Ethernet twisted-pair connection to HiPath HG 1500
The RJ45 cable must be crossed as follows:
1 <> 3
A31003-K5020-S100-4-7620
Service Manual
10/100 BaseT interface contact assignment
X3
1
2
3
6
4+5+7+8
2 <> 6
3 <> 1
LAN boards for Hicom OfficePoint/Com/Pro
Function
Transmit: + wire
Transmit: - wire
Receive: + wire
Receive: - wire
not used
6 <> 2
lan2de.c02
Installation