Sfp Optic Ethernet Ports; Installing An Sfp Optical Port - Siemens RUGGEDCOM RX1501 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

RUGGEDCOM RX1501
Installation Guide
1
Figure 31: SC Port
1. Tx Connector
2. Rx Connector
For specifications on the available fiber optic Ethernet ports, refer to
Specifications".
Section 3.3

SFP Optic Ethernet Ports

SFP (Small Form-Factor Pluggable) optic Ethernet ports are available with LC (Lucent Connector) connectors.
Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to
establish a proper link.
Figure 33: LC Port
1. Tx Connector
2. Rx Connector
NOTE
SFP modules, as well as their optical ports, can be safely inserted and removed while the chassis is
powered and operating.
The following sections describe how to install and remove SFP optical ports:
Section 3.3.1, "Installing an SFP Optical Port"
Section 3.3.2, "Removing an SFP Optical Port"
Section 3.3.1

Installing an SFP Optical Port

To install an SFP optical port, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with
RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability
have not been properly assessed.
SFP Optic Ethernet Ports
2
Figure 32: ST Port
1. Tx Connector
Section 4.5, "Fiber Optic Ethernet Port
1
2
1
2. Rx Connector
Chapter 3
Communication Ports
2
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ruggedcom rx1510

Table of Contents