Toshiba strata DK8 Installation Instructions Manual page 198

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-WIRING DIAGRAMS
SECTION 100-816-208
MARCH 1993
TABLE 8-D
DIGITAL TELEPHDNE/DIU/DDSS
CDNSDLE/ADM/LDDP LIMITS
QPSU/KPSU
Maximum
line length
(24 AWG)
or
I
1 Pair 131~s
MODE
!
Battery
Backup'
!
I
1 Pair
2 Pair
external
power'
I
I
DKT Ringing
(Volume
Max)
QPSWKPSU
Battery
Backup
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 m)
675 ft (204 m)
1000 ft (303 m)
1000 ft (303 m)
DKT with
DVSU (OCA)
QPSWKPSU
Battery
Backup
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 m)
495 ft (150 m)
1000 ft (303 m)
1000 ft (303 m)
DKT with HHEU
I
I
I
I
I
QPSU/KPSU
1 1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 m)
"I
Carbon
Handset
Battery
Backup
330 ft (100 m) 1 1000 ft (303 m) 1 1000 ft (303 m)
DKT with PDIU-DI/
PDIU-D12
QPSWKPSU
495 ft (150 m)
1000 ft (303 m)
1000 ft (303 m)
PDIU-DS
I
Batter-v Backup
I
165 ft (50 m) 1 675 ft (200 m) 1 1000 ft (303 ml
QPSWKPSU
Battery
Backup
I
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 m)
675 ft (204 m)
1000 ft (303 m)
1000 ft (303 m)
DKT with HHEU
and PDIU-DI/PDIU-D12
QPSWKPSU
Battery
Backup
495 ft (150 m)
1000 ft (303 m)
1000 ft (303 m)
33ft(lOm)
330ft(lOOm)
lOOOft(303m)
DDSS2060A
QPSWKPSU
Battery
Backup
QPSWKPSU
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 rn:
500 ft (151 m)
1000 ft (303 m)
1000 ft (303 ml
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 m'
DDCB
Battery
Backup
500 ft (151 m)
1000 ft (303 m)
1000 ft (303 m:
DKT with DVSU
and HHEU
QPSWKPSU
Battery
Backup
1000 ft (303 m)
1000 ft (303 m)
1000 ft (303 rn:
165 ft (50 m)
1000 ft (303 m)
1000 ft (303 m'
DKT with ADM
QPSLVKPSU
Battery
Backup
675 ft (204 m)
1000 ft (303 m)
1000 ft (303 m
165 ft (50 m)
1000 ft (303 m)
1000 ft (303 m)
NOTES:
1. Battery backup applies to instances when the system is being powered
by batteries exclusively.
2. Digital telephones
and other digital devices can operate at maximum
lengths with two pair wiring or an external
power source.
3. See Figure 8-28 for external power wiring.
4. Digital cable runs must not have the following:
l
Cable splits (single or double)
l
Cable bridges (of any length)
l
High resistance or faulty cable splices
8-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk16

Table of Contents