Toshiba strata DK8 Installation Instructions Manual page 159

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-PERIPHERALS
SECTION lOO-816-207
MARCH1993
Disconnect
Timer:
01 DISA
12:24
00:04;57
(incoming)
03 DISA
12:24
00:04;57
(outgoing)
6.03
System
Program
Data Printout.
If a printer
is connected
to the SMDR
port on the QSMU,
PIOU, or PIOUS,
customer
program
information
stored
in the system
RAM may be printed
out for
reference
by using Program
97 (see Paragraph
6.14).
6.10
SMDR
Hardware
Requirements
6.11
The DK8 system
must be equipped
with a
QSMU option PCB. QSMU Program
10-3, LED 04
must be OFF. Install the QSMU PCB in accordance
with Section
100-816-204
and wire the SMDR de-
vice to the QSMU
(PPTC/mocular
cord) in accor-
dance
with Section
100-816-208.
The DK16 sys-
tem must be equipped
with a PIOU or PIOUS PCB
in the Expansion
Unit to support the SMDR printer/
call accounting
device
option.
Connection
of the
printer
or call accounting
device
to the PIOU or
PIOUS PCB is accomplished
with a 3-pair modular
cord (7 feet maximum)
and a PPTC
connector
adaptor
(refer to Figure 7-20 for details). Call record
data is ASCII-formatted,
8 bits, no parity, 1 -stop bit.
6.12
The DK8 KSU and DK16
PIOU or PIOUS
contains
a call record
buffer
which
stores
call
record
data
(for 20 calls on DK8 or 50 calls on
DKI 6) when the printed or call accounting
device is
turned
off, or when no device is connected
to the
SMDR port. No further call records are stored after
the buffer is filled. When the printer or call account-
ing device
is made
operational,
an "ERROR
BUFFER
OVERFLOW"
message
is printed to indi-
cate that the buffer
was full, and that some
call
information
may have been lost.
6.13
SMDR
Programming
Considerations
6.14
Selectable
programming
optionsforthe
SMDR
printer or call accounting
device are:
Program
60
l
Item 2-Determines
the length
of time
a call
must
be active
before
it will be registered
by
SMDR.
l
Item 3-Selects
the records of outgoing
calls or
outgoing
and incoming
calls to be printed.
l
Item 4-Selects
digit length of account
code (4 to
15 digits).
l
Item 5-Allows
only long distance
call records to
be printed.
Program
97
l
Allows system program
data to be printed via the
SMDR port (refer to Figure 7-21 for an example
printout).
NOTES:
1.
2.
An SMDR
printer
must be connected
to
the SMDR port to use the printout
option
selected
by Program
97.
Call record data is lost when program
data
is printed
out using Program
97.
6.20
SMDR
Printer/Call
Accounting
Device
In-
stallation
6.21
Install the SMDR
printer/call
accounting
de-
vice option in accordance
with the following
steps
(refer to Figures 7-20, 8-26, and 8-24):
1)
2)
3)
4)
5)
Connect
the interface
cable
and the PPTC
adaptor from the DK8 QSMU or DKI 6 PIOU or
PIOUS SMDR port to the SMDR printer or call
accounting
device DB25 connector.
Set the DK16 PIOU or PIOUS SW1 switch to
the appropriate
baud rate (300 or 1200 bps),
as determined
by the baud rate of the printer
or call accounting
device.
For DK8, QSMU is
always
1200 bps.
The DK8 QSMU Program
1 O-3, LED 04 must
be OFF for SMDR operation.
Set the printer or call accounting
device to 8-
bits/no parity/one
stop bit.
Program
(Program
60) the system
for the
required
SMDR printer/call
accounting
device
options
(refer to Paragraph
6.13 and the Pro-
gramming
Procedures,
Section 100-816-300).
7-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk16

Table of Contents