Use Program 11-19: Remote Conference Group Pilot Number to assign the remote conference pilot
number for each Remote Conference Group. This is the number a user dials to call into the Remote
Conference.
You must use unassigned extension numbers (e.g., 500) for the pilot number. If you want to use an
extension number which, by default, has a port number assigned (for example: in the 101~199,
3101~3257), first remove the default assignment. For example, to use extension number 125 as a
Remote Conference pilot number, first give extension port 025 a different extension assignment.
Input Data
Item
No.
01

Remote Conference Group Pilot Number

Enter the pilot number for remote conference.
Conditions
None
Feature Cross Reference
None
SV9100 Programming Manual
Program 11 : System Numbering
11-19 : Remote Conference Group Pilot Number
Item
Input Data
Must work within current
system dialing plan
Default
blank