Figure 4-41 . Typical List Display In Compare Trace Mode - HP 1630A Operating And Programming Manual

Logic analyzer
Hide thumbs Also See for 1630A:
Table of Contents

Advertisement

State Measurements
Model 1630A/D/G
[Continuous] LIST DISPLAYS
The list in the continuous trace mode is like the list in the single trace mode, except that "Continuous Trace in
Process" appears at the top . In this mode, the analyzer makes a continuous series of single traces, updating the
display each time it completes a trace. The content of the list will change as each new trace is completed if the
display is updated with different information . To stop a continuous trace, press the STOP key. This causesthe
analyzer to complete its trace in progress and not start a new trace.
[Compare] LIST DISPLAYS
Figure 4-41 shows a typical display that may be obtained in the [Compare/Edit or Full Compare] mode . On the
top line, either the display of [ State ] or [State+Compare] may be selected . If [ State ] is selected, the display
will show only the content of the trace memory, just as you would see in the [Single] trace mode . The
[State+Compare] display is unique to the [Compare/Edit or Full Compare] trace modes .
Display Control Fields
[Overview] LIST DISPLAYS
Figure 4-41 . Typical List Display In Compare Trace Mode
[Mark] :
places integrated display of trace list and Compare list on screen .
[Show] :
places only lines of Compare List on screen in [Show] mode or marks lines of
Compare List in [Mark] mode .
[Compare Image] :
all lines of Compare List can be on screen .
[Differences] :
only lines of Compare List that are different from corresponding lines in trace list
can be on screen in [Show] mode or marked in [Mark] mode .
List or waveform displays may not be obtained when the analyzer is making an overview measurement.
Listing --------- INSERT to Add Compare Item__-
Islt
Labe1>
Base >
ADDRS
ADDR1
®
DATA
®
CNTRL
f
WR-RD
MEMRY
-0006
BOOT
+0433
0433
<STX>
0111
READ
IH-OT
-0007
BOOT
+0433
0433
w
0111
READ
IH-OT
-0006
BOOT
+0102
01132
(
0101
WRITE
IN-OT
-0005
BOOT
+0105
0105
0
0101
WRITE
IN-OT
-0004
BOOT
+01D8
01 D8
8
0101
WRITE
IN-OT
-0003
BOOT
+01DB
010B
<SOH>
0101
WRITE
IN-OT
-0002
BOOT
+01DB
01DB
0101
WRITE
IN-OT
BOOT
+0429
0429
0
0111
READ
IN-OT
+0000
BOOT
+0429
0429
<DC3>
0111
READ
IN-OT
+0000* BOOT 1 +=
+0001
BOOT
+0431
0431
2
0111
READ
IN-OT
+0002
BOOT
+0431
0431
a
0111
READ
IN-OT
+0003
BOOT
+0433
0433
(57X0
0111
READ
IN-OT
+0004
BOOT
+0433
0433
0111
READ
IN-OT
+5005
BOOT
+0102
0102
(
0101
WRITE
IN-OT
+0006
BOOT
+0105
01115
<ES )
0151
WRITE
IN-OT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1630g1630d

Table of Contents