T1 Settings Added for Networking
Parameter
Description
Address
Options
Parameter
Description
Address
Options
Parameter
Description
Address
Options
Page 94
Answer Detect Timer
Sets the minimum time of other end off-hook signal (or
wink) to be interpretted as answer.
FF1 8# 4# 8# 3# (NWG)# 17# (0-8)#
0=50 ms
1=100 ms
2= 200 ms
3=600 ms
4=1000 ms
Flash Output Timer
Sets the duration of a flash output.
FF1 8# 4# 8# 3# (NWG)# 18# (0-15)#
0=no flash
1=200 ms
2=300 ms
3=400 ms
4=500 ms
5=600 ms
6=700 ms
7=800 ms
Flash Detect Timer (Future Use)
Sets the minimum time for a determining a flash.
FF1 8# 4# 8# 3# (NWG)# 19# (0-12)#
0=no flash
1=100 ms
2= 150 ms
3=200 ms
4= 250 ms
5=300 ms
6=350 ms
T1 Networking-Revised April 2000
Programming
5=2000 ms
6=3000 ms
7=4000 ms
8=10000 ms
8=900 ms
9=1000 ms
10=1100 ms
11=1500 ms
12=2000 ms
13=2500 ms
14=3000 ms
15=3500 ms
7=400 ms
8=450 ms
9=500 ms
10=550 ms
11=600 ms
12=650 ms
DBS-2.3/9.2-540