Panasonic DBS Section 540 Reference Manual page 93

T1 networking reference manual
Table of Contents

Advertisement

Programming
Parameter
Description
Address
Options
Parameter
Description
Address
Options
Parameter
Description
Address
Options
DBS-2.3/9.2-540
Wink Signal Output Timer
Sets the duration for a Wink signal.
FF1 8# 4# 8# 3# (NWG)# 14# (0-8)#
0=140 ms
1=160 ms
2=180 ms
3=200 ms
4=220 ms
Wink Signal Detect Timer
Sets the minimum time for determining a wink.
FF1 8# 4# 8# 3# (NWG)# 15# (0-10)#
0=40 ms
1=60 ms
2= 80 ms
3=100 ms
4=120 ms
5=140 ms
Wink Glare Timer (Outpulse Delay)
Sets the time to wait after a wink before signalling on a
trunk.
FF1 8# 4# 8# 3# (NWG)# 16# (0-15)#
0=no wait
1=20 ms
2= 40 ms
3=60 ms
4=80 ms
5=100 ms
6=120 ms
7=140 ms
T1 Networking - Revised April 2000
T1 Settings Added for Networking
5=240 ms
6=260 ms
7=280 ms
8=300 ms
6=160 ms
7=180 ms
8=200 ms
9=220 ms
10=240 ms
8=160 ms
9=180 ms
10=200 ms
11=250 ms
12=300 ms
13=350 ms
14=400 ms
15=450 ms
Page 93