Connecting Stations And Additional Equipment; Connecting Stations; Table 7.1 Distance Between Stations And The System - Samsung OfficeServ 7100 Installation Manual

Hide thumbs Also See for OfficeServ 7100:
Table of Contents

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
PART 7. CONNECTING STATIONS AND ADDITIONAL
EQUIPMENT
This section describes how to connect various stations and additional equipment, such as
analog/digital phones, door phones and door locks, to the OfficeServ 7100 system.

7.1 CONNECTING STATIONS

7.1.1 Safety Precautions
To reduce the risk of personal injury, follow these precautions before connecting telephone
circuits:
• Never install telephone wiring during a lightening storm.
• Never install telephone jacks in a wet location unless the jack is specifically designed for
wet locations.
• Do not connect stations in a humid area.
• Never touch non-insulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
• Connect stations using #24 AWG or #26 AWG cables.
The maximum distance between stations and the OfficeServ 7100 are as follows:
Digital phone
Analog phone
Door phone
AOM (Add-On Module)

Table 7.1 Distance Between Stations and the System

Station
7.1
Home Page
Distance
Maximum 400m/1312ft (for AWG #24)
Maximum 1km/3280ft (for AWG #24)
Maximum 400m/1312ft (for AWG #24)
Maximum 400m/1312ft (for AWG #24)