Sign In
Upload
Manuals
Brands
PerkinElmer Manuals
Laboratory Equipment
PINAACLE 900 Series
PerkinElmer PINAACLE 900 Series Manuals
Manuals and User Guides for PerkinElmer PINAACLE 900 Series. We have
1
PerkinElmer PINAACLE 900 Series manual available for free PDF download: Customer Hardware And Service Manual
PerkinElmer PINAACLE 900 Series Customer Hardware And Service Manual (390 pages)
Brand:
PerkinElmer
| Category:
Laboratory Equipment
| Size: 6.32 MB
Table of Contents
Table of Contents
5
Introduction
13
Safety and Regulatory Information
13
How this Guide Is Organized
15
Conventions Used in this Manual
16
Software Help
16
Chapter 1. Safety Practices
17
Overview
17
Precautions
18
Environmental Conditions
19
Electrical Safety
20
Fuses
22
EMC Compliance
22
Europe
22
United States (FCC)
23
Warning Labels on the Instrument
23
Warning Labels at the Front of the Instrument
25
Warning Labels at the Rear of the Instrument
28
Warning Labels at the Sides of the Instrument
29
Safe Handling of Chemicals
30
Waste Disposal
32
Contents of Waste Containers
32
Disposing of Defective Lamps
32
UV Radiation
34
Magnetic Field
34
Zeeman Graphite Furnace Systems (Pinaacle 900T and Pinaacle 900Z)
34
High Temperatures
35
Burner System
35
Graphite Furnace
35
Quartz Tube Atomizer Cell
36
Handling Compressed Gases
36
Summary of Gas Hazards
37
Identifying Cylinders
38
Safe Handling of Gas Cylinders
38
Identification of Gas Cylinders
39
Storing Cylinders
39
Handling Cylinders
40
Safety Practices for Flame Atomization
40
Safety Interlocks
40
Safe Use of Burner Gases
40
Air Supply
41
Nitrous Oxide (Dinitrogen Monoxide, N2O)
41
Acetylene
42
Safe Operation of the Flame
42
The Drain System
43
Flashbacks
44
Hazards with Flame Atomization
44
Safety Practices for Electrothermal Atomization
45
Safety Interlocks
45
Inert Gas
46
Safety Checks
46
Hazards with Electrothermal Atomization
46
Safety Practices for FIAS and Mercury Hydride Systems
47
Safety Checks
47
Hazards with FIAS and Mercury Hydride Systems
48
Decontamination and Cleaning
49
Decontamination
49
Cleaning the Instrument
49
WEEE Instructions for Perkinelmer Products
50
References for Laboratory Safety Practice
51
Chapter 2. Preparing Your Laboratory
53
Introduction
53
Environmental Requirements
53
Lab Space Requirements
54
Dimensions and Weights
55
Fume Ventilation
57
Vent Hood Dimensions
60
Magnetic Field (Pinaacle 900T and 900Z Only)
62
Line Power Requirements
63
Power Consumption
64
Power Specification Pinaacle 900T and Pinaacle 900Z
64
Power Specification Pinaacle 900H
64
Power Specification Pinaacle 900F
65
Power Specification for the Cooling System
65
Noise Specifications
66
Line Conditioners
66
UPS Systems
68
Power Outlets
68
Gas Requirements
68
Gas Line Connections
69
Safety of Gas Cylinders and Gas Delivery Lines
69
Gas Specifications
71
Furnace Gas Requirements
71
Flame Gas Requirements
72
Atomic Absorption Source Lamps
79
Drain Vessels
80
Cooling Requirements
81
Furnace Cooling
81
Furnace Power Supply Cooling
81
Cooling System
81
External Cooling
81
PC Configuration and Printer
82
Installation Preparation
82
Check for Damage
82
Product Line Experience
83
PC Skills
83
Chapter 3. System Description
85
The Pinaacle 900 Series Spectrometer System
85
Concept
85
Features of the Pinaacle 900 Series System
85
System Components
87
System Control
87
Accessories
88
The Optical System
88
Optical System Schematics for the Pinaacle 900 Series
90
The Electrical Connectors and Switches
94
Operational On/Off Switches
94
Connectors and Controls on the Rear Panel
96
The Gas and Cooling Connectors
97
Furnace Cooling
97
Furnace Gases
97
Burner Gases
97
Burner Assembly System
98
How the Burner System Works
100
Burner Head Options
102
The Burner Mount
103
The Ignitor Assembly
103
Specifications
107
System Design
107
Background Correction
108
Flame Atomizer
108
Graphite Furnace Atomizer
109
Furnace Autosampler
110
Data System
111
Physical Data - Instruments
112
Physical Data - Cooling System
113
Chapter 4. Installation
115
Introduction
115
Unpacking Instructions
117
Inspecting the Shipment
117
Unpacking the Pinaacle 900 Series Spectrometer
117
Banding on the Box
118
How to Unpack the Instrument
118
Recycling the Instrument Box
119
Before You Install the Spectrometer
119
When the Spectrometer Arrives
119
Before the Service Engineer Arrives
119
When the Service Engineer Arrives
120
If You Must Move and Reinstall the Spectrometer
120
Preparing the Spectrometer to be Moved
121
Moving the Spectrometer to Another Location
121
Reinstalling the Spectrometer
123
Connecting the Burner Gases
124
Connecting the Gases
125
Air
125
Nitrous Oxide
125
Acetylene
126
Converting Standard U.S. Gas Lines to European Requirements
127
Connecting the Furnace Gases
128
To Connect Argon (or Nitrogen) Only
129
To Connect both Argon and a Special Gas
131
Connecting the Computer and Printer
133
Electrical Connections
135
Installing the Cooling System
140
Locating the Cooling System
140
Connecting and Disconnecting the Water Hoses
141
Filling the Cooling System
143
Connecting the Drain System to the Burner
144
Preconditioning a Drain Tube
147
Adding Water to the Drain Trap
147
Nebulizer Installation
148
Installing as 900 Furnace Autosampler
148
Installing the Drain Tube and the Waste Bottle
154
Installing Sample Tray and Cover
157
Installing the Sample Capillary
159
Filling and Flushing the Rinsing System
159
To Align the Autosampler Tip in the Graphite Tube
161
Checking the Solution Droplet Delivery
169
Installing S10 Autosampler
172
Lamps
172
Replacement Parts
172
Shipping List for the Pinaacle 900F
173
Shipping List for the Pinaacle 900H
174
Shipping List for the Pinaacle 900T
176
Shipping List for the Pinaacle 900Z
179
Chapter 5. Preparing the System
181
Switching on the System
181
Installing the Lamps
184
Lamp Compartment
185
Installing and Connecting Hcls
186
Electrodeless Discharge Lamps (EDL)
186
Installing and Connecting Edls
186
Removing Lamps
188
Tips for Installing Lamps
188
Installing Sample Trays
189
To Remove the Tray
192
Setting up the System for Analyses Using the Flame Technique
192
Setting up the Burner System
192
Safety Checks for the Flame Technique
193
Igniting the Flame
194
Extinguishing the Flame
195
Setting up the System for Analyses Using the Furnace Technique for the Pinaacle 900 T/Z
197
Locking the Furnace Cover in Place
197
Setting up the Analysis
199
Setting up the System for Analyses Using the Furnace Technique for the Pinaacle 900 H
200
To Use the Furnace
200
Aligning the Graphite Furnace
202
Setting up the as 900 Autosampler
206
Shutting down the System
207
To Shut down the Flame System
207
To Shut down the Furnace System
207
To Shut down the Spectrometer
207
Emergency Shutdown
208
Chapter 6. Maintenance
211
Introduction
211
General Maintenance Checklist
212
Instrument Maintenance Checklist
213
Cleaning the Instrument
214
Checks
214
Periodic Checks
214
Burner Maintenance Checklist
215
Spectrometer Maintenance Checklists
218
General Preventative Maintenance Procedures
218
Spectrometer Maintenance Checklist
218
Changing the Air Filter
219
Changing the Vent Filter
221
Changing the Fuses
222
Cleaning the Burner Chamber
224
Cleaning the Burner Chamber after Use with Organic Solvents
227
Cleaning the Burner Chamber after Aspirating Solutions
228
Containing Cu, Ag, or Hg
228
Cleaning the Burner System
228
Flashbacks
229
Cleaning the Burner Head
230
Quick Cleaning Procedure
230
Complete Cleaning Procedure
231
Checking the Slot Width
231
Pre-Conditioning a New Burner or Drain Tube
232
Removing the Burner Assembly from the Instrument
232
Removing the Burner Head
235
Disassembling the Burner Chamber
235
Reassembling the Burner System
237
To Install the Burner in the Spectrometer
237
To Install the Burner Head
240
Drain System Maintenance
240
Cleaning (or Flushing) the Drain System
242
Emptying the Drain System
243
Replacing the Drain Tubing
244
Preparing the New Drain Tubing for Use
245
Adding Water to the Drain Float Assembly
245
Nebulizer Removal and Reinstallation
246
Removing the Stainless Steel Nebulizer
247
Reinstalling the Stainless Steel Nebulizer
249
Cleaning the Stainless Steel Nebulizer
251
Removing the High Sensitivity Plastic Nebulizer
252
Reinstalling the High Sensitivity Plastic Nebulizer
256
Cleaning the High Sensitivity Plastic Nebulizer
257
Complete Cleaning Procedure of High Sensitivity Plastic Nebulizer
259
Removing and Replacing the High Sensitivity Plastic Nebulizer's Impact Bead
260
Installing the High Sensitivity Plastic Nebulizer Spacer
261
Adjusting the Nebulizer for Maximum Absorbance
261
Using Organic Solvents
262
Maintaining Optimum Nebulizer Performance
263
Replacing Parts of Wear
263
Burner System O-Rings
263
Nebulizer O-Rings
264
Maintaining the Acetylene Supply
265
Lamp Maintenance and Cleaning
266
Lamp Life
266
Lamp Troubleshooting
266
Replacing the Lamps
266
Lamp Compartment Location
267
Removing and Replacing the Deuterium Arc Background Corrector Lamp
268
Removing the Deuterium Lamp Assembly
268
Replacing the Deuterium Lamp
271
Reassembling the Deuterium Lamp Assembly
273
Aligning Deuterium Lamp
273
Resetting the D2 Hours
275
Graphite Furnace Maintenance for the Pinaacle 900T/900Z
276
Removing the Graphite Tube
276
Inserting the Graphite Tube
279
Cleaning the Graphite Tube and Contacts
283
Cleaning the Contact Surfaces of the Graphite Tube and Contacts
285
Changing the Contact Cylinders
286
Tilting the Graphite Furnace Forward
287
Resetting Cycles for Tubes and Contacts
306
Conditioning the Graphite Tube
307
Manually Heating the Graphite Tube
308
Checking and Cleaning the Furnace Windows
309
Tilting the Graphite Furnace Back into Position
312
Graphite Furnace Maintenance for the Pinaacle 900H
312
Open the Furnace and Remove the Graphite Tube
312
Cleaning the Graphite Tube and Graphite Contacts
316
Changing the Graphite Tube
318
Conditioning the Graphite Tube
321
Changing the Graphite Contacts
322
Checking and Cleaning the Furnace Windows
334
S10 Autosampler Maintenance
338
AS 900 Furnace Autosampler Maintenance
338
Filling and Flushing the Rinsing System
339
Valve Maintenance
340
Routine Maintenance
341
Checking the Valves
341
Replacement Parts
343
Replacement Parts for the Pinaacle 900
344
Chapter 7. Troubleshooting
355
Overview
355
Introduction
355
Performance Problems
356
Spectrometer
356
Computer System
358
Burner System
360
Furnace and Furnace Autosampler
364
Autosamplers for Flame and Flow Injection
366
Flow Injection System
366
Analysis Flame Technique
368
Analysis Furnace Technique
370
Analysis Flow Injection Technique
378
Advertisement
Advertisement
Related Products
PerkinElmer Lambda 950
PerkinElmer Panthera-Puncher 9
PerkinElmer 200A Series
PerkinElmer 2081-0010
PerkinElmer aanalyst 200
PerkinElmer ASX-260
PerkinElmer ASX-280
PerkinElmer ASX-520
PerkinElmer ASX-560
PerkinElmer AVIO 200
PerkinElmer Categories
Laboratory Equipment
Measuring Instruments
Dispenser
All in One Printer
eBook Reader
More PerkinElmer Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL