Notifier AFP-200 Installation Manual (196 pages)
Analog Fire Panel
Brand:
Notifier
| Category:
Fire Alarms
| Size: 5.74 MB
Table of Contents
Installation Precautions
3
Table of Contents
4
About this Manual
10
Section 1 System Overview
14
General Description
14
Features
14
Components
15
Membrane Switch Panel
15
Panel Sounder
16
Output Circuits (TB2)
16
Relays (TB3)
16
Main Assemblies
17
CPU Board
17
Cabinet
18
LCD Display
18
Membrane Switch Panel
18
Transformer Assembly
18
Batteries
18
Optional Devices & Option Modules
19
Digital Communicator
19
Udact
19
Network Interface Board - NIB-96
19
Field Charger/Power Supply - FCPS-24
20
Battery Charger - CHG-120
20
Liquid Crystal Display - LCD-80
20
Option Module: Transmitter Module - 4XTM
20
Option Module: Relay/Transmitter Module - RTM-8
20
Meter Module
20
Trim Ring
21
Battery Box
21
Dress Panel
21
Expansion Power Supplies (AVPS-24 and APS-6R)
21
Marine Cabinet
21
Intelligent Detectors
21
Addressable Modules
22
Overview
22
Module Descriptions
22
End-Of-Line Devices
24
Overview
24
Annunciation Modules
24
Annunciator Control Module-8R (ACM-8R)
24
LDM Series Lamp Driver Modules
24
Annunciator Control System (ACS)
25
Annunciator Fixed Modules
25
Peripheral Devices (TB4)
26
Overview
26
PRN Remote Printer
26
Keltron Remote Printer (Model VS4095)
26
Display Terminal
26
Specifications
27
Primary AC Power (TB7)
27
Battery (Lead-Acid Only)
27
Signaling Line Circuit (TB6)
27
Notification Appliance and Releasing Circuits (TB2)
27
Relays (TB3)
28
VDC Power (TB1)
28
Cabinet Dimensions
28
Surface Mount with a BB-17 Battery Box
28
Semi-Flush Mount
29
Section 2 Installation
30
Preparing for Installation
30
Unpacking the System
30
Installation Notes
30
Standards and Codes
30
Installation Checklist
31
Backbox Mounting
32
AC and DC Power Connections
33
AC Power Connections (TB7)
33
Battery Power Connection (J3)
34
Expansion Power Supplies - AVPS-24 or APS-6R (Optional)
34
DC Output Power Connections (TB1)
35
Output Circuits (TB2)
35
Notification Appliance Circuits
35
Standard Relays (TB3)
36
Devices - Remote Printers and Crts (TB4)
37
Overview
37
Eia-232 Devices – Remote Printers and Crts (Tb)
37
Printer Configuration
37
Installation
37
Keltron Printer
38
CRT Connections
39
Wiring a Signaling Line Circuit (SLC)
41
Overview of SLC Wiring
41
SLC Devices
42
Control Panel Capacity
42
SLC Performance
43
SLC Shield Termination
43
Setting an SLC Address for a Module
44
Wire Requirements for a Two-Wire SLC
45
Wire Requirements for a Four-Wire SLC
46
Four-Wire SLC Overview
49
Wiring an Isolator Module (ISO-X)
49
Wiring an IDC with Monitor Modules
50
Wiring a Notification Appliance Circuit (NAC) or Control Circuit
56
SLC Wiring with Control Modules
57
SLC Wiring with an Intelligent Detector
59
SLC Wiring with an NBG-12LX Addressable Manual Pull Station
60
Option Module Installation
61
Overview
61
Installing a 4XTM Module
62
Installing an RTM-8 Module
63
Section 3 Programming
65
Overview
65
Programming Methods
65
In this Section
65
Getting Started
66
How to Access Programming Options
66
Programming Passwords
66
How to Use the Programming Keypad
67
Programming Shortcuts
68
Upload and Download
68
Key Programming Terms
68
How to Avoid Programming Errors
69
Program Change Options
70
Overview
70
How to Enter Program Change
71
Program Change Map
72
How to Clear a Program from Memory (0=Clr)
73
How to Autoprogram the Control Panel (1=Auto)
73
How to Edit or Delete a Point (2=Point)
78
How to Change a Programming Password (3=Passwd)
85
How to Change a System Message (4=Message)
86
How to Change a Zone Label (5=Zones)
86
How to Edit a Special Zone (6=Spl Zones)
87
How to Edit System Functions (7=Sys)
89
How to Check the Program (8=Check)
92
Status Change Options
92
Overview
92
Entering Status Change
93
Status Change Programming Map
94
How to Disable or Enable a Point (1=Disable)
95
How to Set Detector Selections (2=Sens/Comp)
96
How to Clear Alarm Verification Counters (3=Clr Ver)
97
How to Clear the History Buffer (4=Clr Hist)
98
How to Set the System Time and Date (5=Time)
98
How to Do a Walk Test (6=Walk Test)
99
Section 4 Operation
101
Overview
101
The Membrane Panel
102
Overview
102
How to Use the Programming Keypad
102
How to Use the Enter Key and Cursor Keys
103
How to Use the Operator Keys
103
How to Read System Status LED Indicators
105
How to Operate the Control Panel
106
How to Operate the Panel in Normal Operation
107
How to Operate a Panel with a Trouble Condition
107
How to Operate a Panel with a Trouble Monitor Point
109
How to Operate a Panel with a Fire Alarm
109
How to Operate a Panel with a Supervisory Condition
110
How to Operate a Panel with a Non-Alarm Condition
111
How to Operate the Panel with an Output Circuit Trouble
111
How the Control Panel Indicates a Panel Circuit Trouble
112
Control-By-Event Operation
112
Releasing Functions
113
Overview
113
How to Select Cross Zone Options
113
Releasing Functions
114
Intelligent Detector Functions
115
Summary of Detector Functions
115
Pre-Alarm Operation/Advanced Warning Addressable Combustion Sensing (AWACS™)
115
Time Functions
116
Overview
116
Coding Operation (NAC Only)
117
Presignal/Pas Operation
117
Special System Timers
118
Waterflow Circuits Operation
118
Disable/Enable Operation
118
Style 6 Operation
118
Read Status
118
Overview
118
How to Enter Read Status
119
Read Status Options
119
Read Point
119
Using the History Buffer
124
Appendix A Power Supply Calculations
126
Overview
126
Calculating the AC Branch Circuit
126
The Main Power Supply
127
Current Limitations in Standby
127
Current Limitations in Alarm - System Operation on Primary Power
127
Calculating the System Current Draw
128
Overview
128
How to Use Table 47 to Calculate System Current Draws
128
Calculating the Battery Size
130
Selecting and Locating Batteries
131
NFPA Battery Requirements
131
Appendix B NFPA Applications
132
Section Overview
132
Specific Requirements
132
Additional Requirements
132
Central Station Fire Alarm Systems (Protected Premises)
133
Installing a Notifier 911AC
133
Installing a UDACT
134
NFPA 72 Auxiliary Fire Alarm System
135
Wiring a Remote Station Fire Alarm System
136
Overview
136
Using a 4XTM Module
137
Using an RTM-8 Module
138
NFPA 72 Proprietary Fire Alarm Systems
138
Appendix C Annunciators
140
Display
140
ACS Mode
140
Terminal Mode
140
Terminal Mode (LCD-80) Annunciation Interface (TB5 on CPU)
140
ACS Annunciation Interface (TB5 on CPU)
141
Supported Modules
141
Annunciator Capacity
141
Data Formats for Annunciator Address 1
141
Data Formats at Annunciator Address 2
141
Terminal Mode EIA-485 Connections (TB5)
144
ACS Mode EIA-485 Connections
145
Power Connections for LCD and ACS Series Annunciators
146
ACS and LDM Series EIA-485 Connections
147
Appendix D Releasing Applications
148
NFPA Standards
148
Programming Releasing Zones
148
Releasing Zone Functions
149
Delay Timer
149
Cross Zoning
149
Soak Timer (NFPA 16 Applications Only)
150
Abort Timer
151
Special Module Type Codes
151
Abort Switch
151
Man. Release
151
Rel Ckt ULC
152
Release Ckt
152
Initiating Devices
152
Warning Sounders
152
Auxiliary Control Relay Functions
153
ACS Annunciation
153
Deluge/Pre-Action Release
153
Connecting Releasing Devices
153
Connecting a Releasing Device to a Control Panel through an SLC Control or Relay Module
154
Connecting an NBG-12LRA Agent Releasing Abort Station
154
Appendix E Combination Fire/Burglary Applications
157
Overview
157
Installation
157
Installation Overview
157
Installing a Tamper Switch
157
Wiring for Proprietary Security Alarm Applications
158
Connecting to an AM2020/AFP1010 Receiving Unit
159
Programming
159
Operation
160
Overview
160
Configuring the Keypad for a Security LED Indicator
160
Control Panel Operation in a Security Condition
160
Appendix F Wire Requirements
161
Appendix G Pre-Alarm (AWACS™) Applications
162
Overview
162
Pre-Alarm Applications
162
Pre-Alarm Alert Level
162
Action Level Pre-Alarm Function
163
Pre-Alarm Programming
163
Pre-Alarm Programming Screen
163
Selecting Pre-Alarm Application Levels
164
Self-Optimizing Pre-Alarm Function
165
Audible Warning Applications for AWACS
166
Appendix H Special Zones
167
Overview
167
Presignal and Positive Alarm Sequence (PAS)
167
Presignal
167
Positive Alarm Sequence (PAS)
167
Time Control
168
NAC Code Types
168
Appendix I Terminal Interface Protocol
169
General Description
169
Operating Modes
169
Local Terminal Mode (Loct)
169
Local Monitor Mode (Locm)
170
Remote Terminal Mode (Remt)
170
Using the CRT-2 for Read Status
171
Overview
171
Accessing Read Status Options
171
Read Point
172
Display Devices in Alarm or Trouble
172
Display the Status of All Programmed Points
172
View the History Buffer
173
Send the History Buffer to the CRT-2
173
Using the CRT-2 for Alter Status
173
Overview
173
Accessing Alter Status Options
174
Enable or Disable Detectors, Modules, or Bell Circuits
174
Change Detector Sensitivity Levels
175
Clear the Verification Counter
175
Clear the Entire History Buffer
175
Set the Pre-Alarm for Alert or Action Level
176
Configuration
176
Appendix J Expansion Power Supplies
177
Overview
177
AVPS-24 Audio/Visual Power Supply
177
APS-6R Auxiliary Power Supply
177
Programming
179
Supply Calculations
179
AVPS-24/AVPS-24E Calculations
179
APS-6R Calculations
180
Installation
180
Installing the AVPS-24/AVPS-24E
180
Installing the APS-6R
183
Appendix K UL Power-Limited Wiring Requirements
186
Overview
186
Typical Circuit with Nonpower-Limited and Power-Limited Wiring
186
Appendix L U.S. Coast Guard & Lloyd's Register
187
Appendix M CBE Programming
189
Purpose
189
Software Zones
189
How to Program CBE
189
CBE Example 1
189
CBE Example 2
190
Appendix N External Battery Charger
191
Overview
191
Installation Requirements
191
Mounting the CHG-120
191
Mounting the Charger into a CAB-X3 Series Cabinet
191
Mounting the Charger into a Battery Box
192
Connecting the CHG-120
194
Connecting a CHG-120 to the AFP-200
194
Limited Warranty
195
Advertisement
Notifier AFP-200 Instruction Manual (120 pages)
Intelligent fire detection and alarm system
Brand:
Notifier
| Category:
Security System
| Size: 3.91 MB
Table of Contents
Table of Contents
3
1.5 Controls and Indicators
9
1.4 AFP-200 Features
9
Membrane Panel
9
Components
11
1.7 Optional Devices
13
Udact
13
Specifications
27
2.2 Backbox Mounting
29
2.1 Installation Overview
29
Power
29
2.7 Wiring the Signaling Line Circuit
31
2.6 Remote Printers/Crt
31
The Isolator Module
31
Optional Modules
45
3.2 Program Change Operation
50
3.1 Program/Status Change Entry
50
Clear
50
Point Programming
52
Password Change
54
Zone Change
55
Upload/Download
56
Status Change Operation
57
Walk Test
58
4.1 Switch Functions
59
Acknowledge/Step
59
4.2 LED Indicators
61
Normal Operation
61
Trouble Operation
62
4.10 Control-By-Event Operation
63
4.9 Notification Appliance Circuit Operation
63
Releasing Functions
63
4.12 Intelligent Detector Functions
65
Time Functions
65
Notifier AFP-200 Manual (12 pages)
Liquid Crystal Display Fire Alarm Control Panels
Brand:
Notifier
| Category:
Fire Alarms
| Size: 0.6 MB
Table of Contents
Liquid Crystal Display
1
Table of Contents
3
Section One: LCD-80TM Features
4
Section Two: Operating the LCD-80TM
6
Display Patterns
6
Status Button
6
Contrast Adjust
6
Lamp Test Button
6
Global Acknowledge Button
6
Silence Button
6
Reset Button
6
Section Three: LCD-80TM Electrical Connections
7
Connecting the EIA-485 Interface
7
Connecting +24 VDC Power
8
Appendix A: EIA-485 Shield Terminations
9
Limited Warranty
12
Advertisement
Notifier AFP-200 Manual (2 pages)
Door, Backbox, and Dress Panel Assembly
Brand:
Notifier
| Category:
Control Panel
| Size: 1.02 MB
Advertisement
Related Products
Notifier AFP1010
Notifier AFP-100
Notifier AFP-100e
Notifier AM2020
Notifier AFC-600
Notifier ACS Series
Notifier AVL-1
Notifier AFP-3030
Notifier AFP-300
Notifier AFP-400
Notifier Categories
Fire Alarms
Control Panel
Smoke Alarm
Control Unit
Security System
More Notifier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL