Manuals and User Guides for Emerson Rosemount 3051. We have
28
Emerson Rosemount 3051 manuals available for free PDF download: Reference Manual, Manual, Quick Start Manual, Operating Instructions Manual, Quick Installation Manual
Emerson Rosemount 3051 - Pressure Transmitter Manual
Brand:
Emerson
| Category:
Transmitter
| Size: 3.52 MB
Table of Contents
About this guide
System readiness
Confirm correct device driver
Transmitter installation
Mounting the transmitter
Mount the transmitter in liquid applications
Mount the transmitter in gas applications
Mount the transmitter in steam applications
Assemble the transmitter
In-line gage transmitter orientation
Consider housing rotation
Set the switches
Connect the wiring and power up
Grounding for transient terminal block
Verifying configuration
Verifying configuration with a Field Communicator
Verify configuration with local operator interface (LOI)
Switch HART revision mode
Trim the transmitter
Trimming with a Field Communicator
Safety instrumented systems installation
Safety messages
Documents / Resources
References
Advertisement
Emerson Rosemount 3051 Reference Manual (222 pages)
Pressure Transmitter with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 7.02 MB
Table of Contents
Table of Contents
5
1Section 1: Introduction
11
Using this Manual
11
Service Support
11
Models Covered
12
Transmitter Overview
13
Product Recycling/ Disposal
14
Overview
15
Safety Messages
15
General Considerations
16
Mechanical Considerations
17
Draft Range Considerations
17
Environmental Considerations
18
HART Installation Flowchart
19
Installation Procedures
20
Mount the Transmitter
20
Impulse Piping
24
Process Connections
26
Inline Process Connection
28
Housing Rotation
28
LCD Display
29
Configure Security and Alarm
30
Electrical Considerations
32
Conduit Installation
32
Wiring
33
Transient Protection Terminal Block
36
Grounding
37
Hazardous Locations Certifications
39
Rosemount 305, 306, and 304 Manifolds
39
1Rosemount 305 Integral Manifold Installation Procedure
41
2Rosemount 306 Integral Manifold Installation Procedure
41
3Rosemount 304 Conventional Manifold Installation Procedure
41
4Manifold Operation
41
Liquid Level Measurement
44
1Open Vessels
45
2Closed Vessels
45
Overview
49
Safety Messages
49
Commissioning
50
Setting the Loop to Manual
50
Wiring Diagrams
51
Configuration Data Review
52
Field Communicator
52
Field Communicator User Interface
53
Field Communicator Menu Trees
54
Traditional Fast Key Sequence
58
Check Output
60
Process Variables
61
Sensor Temperature
61
Basic Setup
62
Set Process Variable Units
62
Set Output (Transfer Function)
62
Rerange
63
Damping
67
LCD Display
68
1LCD Display Configuration for 4-20 Ma HART Only
69
2Custom Display Configuration 4-20 Ma HART Only
69
Detailed Setup
71
1Failure Mode Alarm and Saturation
71
2Alarm and Saturation Levels for Burst Mode
72
3Alarm and Saturation Values for Multidrop Mode
72
4Alarm Level Verification
72
Diagnostics and Service
72
1Loop Test
72
Advanced Functions
74
1Saving, Recalling, and Cloning Configuration Data
74
2Burst Mode
77
Multidrop Communication
78
Changing a Transmitter Address
79
1Communicating with a Multidropped Transmitter
79
2Polling a Multidropped Transmitter
79
Overview
81
Safety Messages
81
Warnings
82
Calibration Overview
82
Determining Calibration Frequency
84
Choosing a Trim Procedure
86
Analog Output Trim
87
Digital-To-Analog Trim
87
Digital-To-Analog Trim Using Other Scale
89
Recall Factory Trim-Analog Output
90
Sensor Trim
91
Sensor Trim Overview
91
Zero Trim
92
Sensor Trim
93
Recall Factory Trim-Sensor Trim
94
Line Pressure Effect (Range 2 and Range 3)
94
Compensating for Line Pressure
95
Overview
99
Safety Messages
99
Warnings ()
100
Diagnostic Messages
102
Write Protect
104
Disassembly Procedures
107
Remove from Service
108
Remove Terminal Block
109
Remove the Electronics Board
109
Remove the Sensor Module from the Electronics Housing
109
Reassembly Procedures
110
Attach the Electronics Board
110
Install the Terminal Block
111
Reassemble the 3051C Process Flange
111
Install the Drain/Vent Valve
112
Performance Specifications
113
Conformance to Specification (±3S (Sigma))
113
Reference Accuracy (1)
114
Total Performance
114
A.1.2 Reference Accuracy (1)
114
Long Term Stability
115
Dynamic Performance
115
Line Pressure Effect Per 1000 Psi (6,9 Mpa)
115
Ambient Temperature Effect Per 50 °F (28 °C)
116
Mounting Position Effects
116
Vibration Effect
116
A.1.10Power Supply Effect
117
A.1.11Electromagnetic Compatibility (EMC)
117
A.1.12Transient Protection (Option Code T1)
117
Emerson Rosemount 3051 Reference Manual (198 pages)
pressure transmitter with PROFIBUS PA Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 11.62 MB
Table of Contents
Table of Contents
3
Using this Manual
11
Models Covered
11
Device Revisions
12
Transmitter Overview
12
Product Recycling/Disposal
12
Section Overview
13
Safety Messages
13
Hazardous Locations Certifications
14
Configuration Guidelines
14
Profile 3.02 Identification Number Adaptation Mode
14
Block Modes
14
Configuration Tools
15
Basic Setup Tasks
15
Assign Address
15
Pressure Configuration
15
Detailed Setup Tasks
17
Flow Configuration
17
Class Two Master
18
Level Configuration
19
Damping
20
Process Alerts
20
LCD Display
21
Security
21
LOI Security
22
Simulation
22
Section Overview
23
Safety Messages
23
Installation Considerations
23
Refer to the Following Safety Messages before
23
Performing an Operation Preceded by this Symbol
23
Explosions Could Result in Death or Serious Injury
23
When Power Is Applied to the Unit
23
Process Leaks May Cause Harm or Result in Death
23
Install and Tighten Process Connectors before Applying Pressure
23
Electrical Shock Can Result in Death or Serious Injury
23
Mechanical Considerations
24
Environmental Considerations
24
Installation Procedures
24
Mount the Transmitter
24
Impulse Piping
29
Process Connections
31
In-Line Process Connection
32
Rosemount 305, 306 and 304 Manifolds
33
Rosemount 305 Integral Manifold Installation Procedure
33
Rosemount 306 Integral Manifold Installation Procedure
34
Rosemount 304 Conventional Manifold Installation Procedure
34
Manifold Operation
34
Liquid Level Measurement
39
Open Vessels
40
Closed Vessels
40
Section Overview
43
Safety Messages
43
LCD Display
44
LCD Display with Local Operator Interface (LOI)
44
Configure Security and Simulation
44
Security (Write Protect)
44
Simulate
45
Electrical Considerations
45
Conduit Installation
45
Wiring
46
Signal Wiring Grounding
47
Transient Protection Terminal Block
48
Grounding
49
Section Overview
51
Safety Messages
51
Calibration Overview
52
Zero Trim
52
Sensor Trim
52
Recall Factory Trim
52
Determining Calibration Frequency
53
Sensor Trim
54
Zero Trim
54
Recall Factory Trim
55
Compensating for Line Pressure
55
Range 2 and 3
55
Range 4 and Range 5
56
Section Overview
57
Safety Messages
57
Service Support
58
Diagnostics Identification and Recommended Action
58
Extended Diagnostics Identification with Class One Master
59
Plantweb ™ and NE107 Diagnostics
61
Alert Messages and Fail Safe Type Selection
61
Disassembly Procedures
63
Remove from Service
63
Remove Terminal Block
63
Remove the Electronics Board
63
Remove the Sensor Module from the Electronics Housing
64
Reassembly Procedures
64
Attach the Electronics Board
65
Install the Terminal Block
65
Reassemble the Rosemount 3051C Process Flange
65
Install the Drain/Vent Valve
66
Performance Specifications
67
Conformance to Specification (±3S [Sigma])
67
Reference Accuracy
67
A.1 Performance Specifications
67
Flow Performance - Flow Reference Accuracy
68
Total Performance
68
Long Term Stability
68
A.1.4 Total Performance
68
Dynamic Performance
69
Line Pressure Effect Per 1000 Psi (68,95 Bar)
69
Ambient Temperature Effect Per 50 °F (28 °C)
69
A.1.6 Dynamic Performance
69
Mounting Position Effects
70
Vibration Effect
70
Power Supply Effect
70
Electromagnetic Compatibility (EMC)
70
Transient Protection (Option Code T1)
70
Functional Specifications
70
Range and Sensor Limits
70
4-20 Ma HART (Output Code A)
71
Output
71
A.2.2 4–20 Ma HART (Output Code A)
71
Foundation Fieldbus (Output Code F)
72
PROFIBUS PA (Output Code W)
73
Wireless (Output Code X)
73
Low Power Output
74
Overpressure Limits
74
Static Pressure Limit
74
Burst Pressure Limits
75
Failure Mode Alarm
75
Temperature Limits
75
Humidity Limits
76
Turn-On Time
76
Volumetric Displacement
76
Damping
76
Physical Specifications
76
Material Selection
76
Electrical Connections
76
Process Connections
76
Process-Wetted Parts
76
A.2.13 Humidity Limits
76
Rosemount 3051L Process Wetted Parts
77
Non-Wetted Parts
77
Shipping Weights
77
Advertisement
Emerson Rosemount 3051 Reference Manual (186 pages)
Pressure Transmitter with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 12.1 MB
Table of Contents
Table of Contents
3
Using this Manual
11
Models Covered
11
Product Recycling/ Disposal
12
Overview
13
Safety Messages
13
Commissioning
14
Setting the Loop to Manual
14
Wiring Diagrams
14
Configuration Data Review
16
Field Communicator
17
Field Communicator User Interface
17
Field Communicator Menu Trees
18
Traditional Fast Key Sequence
22
Check Output
24
Process Variables
25
Sensor Temperature
25
Basic Setup
25
Set Process Variable Units
25
Set Output (Transfer Function)
26
Rerange
27
Damping
30
LCD Display
31
LCD Display Configuration for 4-20 Ma HART Only
31
Custom Display Configuration 4-20 Ma HART Only
32
Detailed Setup
33
Failure Mode Alarm and Saturation
33
Alarm and Saturation Levels for Burst Mode
34
Alarm and Saturation Values for Multidrop Mode
34
Alarm Level Verification
34
Diagnostics and Service
34
Loop Test
34
Contents
36
Burst Mode
38
Advanced Functions
36
Saving, Recalling, and Cloning Configuration Data
36
Multidrop Communication
39
Changing a Transmitter Address
40
Communicating with a Multidropped Transmitter
40
Polling a Multidropped Transmitter
40
Overview
41
Safety Messages
41
General Considerations
42
Mechanical Considerations
42
Draft Range Considerations
43
Environmental Considerations
43
HART Installation Flowchart
44
Installation Procedures
45
Mount the Transmitter
45
Impulse Piping
49
Process Connections
51
Inline Process Connection
52
Housing Rotation
53
LCD Display
54
Configure Security and Alarm
54
Electrical Considerations
56
Conduit Installation
56
Wiring
56
Transient Protection Terminal Block
58
Grounding
60
Hazardous Locations Certifications
61
Rosemount 305, 306, and 304 Manifolds
61
Rosemount 305 Integral Manifold Installation Procedure
62
Rosemount 306 Integral Manifold Installation Procedure
63
Rosemount 304 Conventional Manifold Installation Procedure
63
Manifold Operation
63
Valve Components
68
Liquid Level Measurement
69
Open Vessels
69
Closed Vessels
69
Overview
73
Safety Messages
73
Calibration Overview
74
Determining Calibration Frequency
76
Selecting a Trim Procedure
78
Analog Output Trim
78
Digital-To-Analog Trim
79
Digital-To-Analog Trim Using Other Scale
80
Recall Factory Trim-Analog Output
81
Sensor Trim
81
Sensor Trim Overview
81
Zero Trim
82
Sensor Trim
83
Recall Factory Trim-Sensor Trim
84
Line Pressure Effect (Range 2 and 3)
84
Compensating for Line Pressure
85
Overview
87
Safety Messages
87
Diagnostic Messages
89
Write Protect
91
Disassembly Procedures
94
Remove from Service
94
Remove Terminal Block
94
Remove the Electronics Board
95
Remove the Sensor Module from the Electronics Housing
95
Reassembly Procedures
95
Attach the Electronics Board
96
Install the Terminal Block
96
Reassemble the Rosemount 3051C Process Flange
96
Performance Specifications
99
Conformance to Specification (±3S [Sigma])
99
Reference Accuracy
99
A.1 Performance Specifications
99
Total Performance
100
Long Term Stability
100
Specifications and Reference Data
100
A.1.3 Total Performance
100
Dynamic Performance
101
Line Pressure Effect Per 1000 Psi (6,9 Mpa)
101
Ambient Temperature Effect Per 50 °F (28 °C)
101
A.1.5 Dynamic Performance
101
Mounting Position Effects
102
Vibration Effect
102
Power Supply Effect
102
Electromagnetic Compatibility (EMC)92
102
Transient Protection (Option Code T1)
102
Emerson Rosemount 3051 Reference Manual (160 pages)
Wireless Series Pressure, Level, and Flow Solutions with WirelessHART Protocol
Brand:
Emerson
| Category:
Transducer
| Size: 4.06 MB
Table of Contents
Table of Contents
7
1Section 1: Introduction
13
Using this Manual
13
Models Covered
13
Rosemount 3051CD Differential Pressure Transmitter
13
Rosemount 3051CG Gage Pressure Transmitter
13
Rosemount 3051CA Absolute Pressure Transmitter
13
Rosemount 3051T Gage and Absolute Pressure Transmitter
14
Rosemount 3051L Liquid Level Transmitter
14
Wirelesshart Installation Flowchart
15
Transmitter Overview
16
Considerations before Transmitter Installation
17
Wireless Considerations
17
Mechanical
18
Electrical
18
Environmental
18
Service Support
19
Product Recycling/Disposal
20
Overview
21
Safety Messages
21
Warnings ()
22
Required Bench Top Configuration
22
Connection Diagrams
22
Device Network Configuration
23
Join Device to Network
23
Configure Update Rate
24
Remove Power Module
24
Review Configuration Data
25
Review Pressure Information
25
Review Device Information
25
Review Sensor Information
27
Review Radio Information
27
Field Communicator
28
Basic Setup
29
Set Process Variable Unit
29
Set Transfer Function
31
Damping
32
Write Protect
32
Check Output
29
Operating Parameters
29
LCD Display
33
LCD Display Configuration
33
Detailed Setup
34
1Configure Process Alarms
34
2Sensor Temperature Unit
35
Diagnostics and Service
35
1Master Reset
35
2Join Status
35
3Number of Available Neighbors
36
Advanced Functions for HART Protocol
37
1Saving, Recalling, and Cloning Configuration Data
37
Overview
39
Safety Messages
39
Warnings ()
40
Considerations
41
General
41
Wireless
41
Mechanical
41
Environmental
42
Installation Procedures
43
Mount the Transmitter
43
Process Connections
46
Consider Housing Rotation
48
Grounding
48
Power Module Installation
49
Installing the LCD Display
49
Rosemount 304, 305 and 306 Integral Manifolds
50
Rosemount 305 Integral Manifold Installation Procedure
51
Rosemount 306 Integral Manifold Installation Procedure
51
Rosemount 304 Conventional Manifold Installation Procedure
52
Manifold Operation
52
Rev AA June
56
Safety Messages
59
Warnings ()
59
Network Status
60
Verify Operation
60
Troubleshooting
62
Overview
63
Calibration
63
Sensor Trim Overview
64
Zero Trim
65
Sensor Trim
65
Recall Factory Trim-Sensor Trim
66
Line Pressure Effect (Range 2 and Range 3)
66
Compensating for Line Pressure (Range 4 and Range 5)
66
LCD Screen Messages
69
Startup Screen Sequence
69
Diagnostic Button Screen Sequence
71
Network Diagnostic Status Screens
72
Device Diagnostic Screens
75
Overview
79
Safety Messages
79
Warnings ()
80
Disassembly Procedures
84
Removing from Service
84
Removing the Electronics Board
85
Removing the Sensor from the Housing
86
Reassembly Procedures
87
Attaching Electronics Board
87
Reassembling the 3051C Process Flange
87
Installing Drain/Vent Valve
89
Performance Specifications
91
Conformance to Specification (±3S (Sigma))
91
Digital Output
91
A.1 Performance Specifications
91
Reference Accuracy
92
Flow Performance - Flow Reference Accuracy
92
A.1.3 Reference Accuracy
92
Total Performance
93
A.1.5 Total Performance
93
Long Term Stability
94
Dynamic Performance
94
Line Pressure Effect Per 1000 Psi (6,9 Mpa)
94
Ambient Temperature Effect Per 50°F (28°C)
95
A.1.10Mounting Position Effects
95
A.1.11Vibration Effect
95
A.1.12Power Supply Effect
95
A.1.13Electromagnetic Compatibility (EMC)
95
Emerson Rosemount 3051 Reference Manual (136 pages)
Pressure Transmitter with 4-20 mA HART Revision 5 and 7 Selectable Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 6.43 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
7
Using this Manual
7
Models Covered
7
Product Recycling/Disposal
8
Chapter 2 Configuration
9
Overview
9
Safety Messages
9
System Readiness
10
Configuration Basics
11
Setting the Loop to Manual
14
Verify Configuration
15
Basic Setup of the Transmitter
16
Configuring the LCD Display
25
Detailed Transmitter Setup
26
Configuring Transmitter Diagnostics
33
Performing Transmitter Tests
37
Configuring Burst Mode
39
Establishing Multidrop Communication
41
Chapter 3 Hardware Installation
45
Overview
45
Safety Messages
45
Considerations
46
Installation Procedures
48
Chapter 4 Electrical Installation
69
Overview
69
Safety Messages
69
LCD Display
70
Configuring Transmitter Security
71
Set Transmitter Alarm
75
Electrical Considerations
76
Chapter 5 Operation and Maintenance
83
Overview
83
Safety Messages
83
Recommended Calibration Tasks
84
Calibration Overview
85
Trim the Pressure Signal
89
Trim the Analog Output
93
Switching HART ® Revision
98
Chapter 6 Troubleshooting
101
Overview
101
Safety Messages
101
Troubleshooting for 4-20 Ma Output
102
Diagnostic Messages
103
Disassembly Procedures
109
Reassemble
111
Service Support
114
Chapter 7 Safety Instrumented Systems (SIS) Requirements
117
Identify Rosemount ™ 3051 Safety Certification
117
Installation in SIS Applications
117
Configuring in SIS Applications
118
SIS Operation and Maintenance
119
Inspection
121
Emerson Rosemount 3051 Manual (132 pages)
Pressure Transmitter with 4-20 mA HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 8.04 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
7
Models Covered
7
Product Recycling/Disposal
7
Chapter 2 Configuration
9
Overview
9
Safety Messages
9
System Readiness
9
Configuration Tools
11
How to Configure
15
Application Specific Configuration
22
Detailed Transmitter Setup
29
Configure Via Bluetooth ® Wireless Technology
32
Configuring Transmitter Diagnostics
33
Performing Transmitter Tests
39
Configuring Burst Mode
41
Establishing Multidrop Communication
42
Chapter 3 Hardware Installation
45
Overview
45
Safety Messages
45
Considerations
45
Installation Procedures
47
Chapter 4 Electrical Installation
71
Overview
71
Safety Messages
71
Install LCD Display
71
Configuring Transmitter Security
73
Move Alarm Switch
74
Electrical Considerations
75
Chapter 5 Operation and Maintenance
83
Overview
83
Safety Messages
83
Recommended Calibration Tasks
83
Calibration Overview
84
Trimming the Pressure Signal
88
Trimming the Analog Output
91
Chapter 6 Troubleshooting
95
Overview
95
Safety Messages
95
Troubleshooting for 4-20 Ma Output
95
Diagnostic Messages
97
Disassembling the Transmitter
103
Reassemble the Transmitter
105
Chapter 7 Safety Instrumented Systems (SIS) Requirements
109
Identify Rosemount 3051 Safety Certification
109
Installation in Safety Instrumented Systems (SIS) Applications
109
Configuring in Safety Instrumented Systems (SIS) Applications
110
Safety Instrumented Systems (SIS) Operation and Maintenance
111
Inspection
113
Emerson Rosemount 3051 Manual (122 pages)
Pressure Transmitter with 4-20 mA HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 8.78 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
7
Models Covered
7
Product Recycling/Disposal
7
Chapter 2 Configuration
9
Overview
9
Safety Messages
9
System Readiness
9
Configuration Tools
11
How to Configure
14
Application Specific Configuration
21
Detailed Transmitter Setup
28
Configure Via Bluetooth ® Wireless Technology
32
Configuring Transmitter Diagnostics
32
Performing Transmitter Tests
38
Configuring Burst Mode
39
Establishing Multidrop Communication
40
Chapter 3 Hardware Installation
43
Overview
43
Safety Messages
43
Considerations
43
Installation Procedures
45
Chapter 4 Electrical Installation
65
Overview
65
Safety Messages
65
Install LCD Display
65
Configuring Transmitter Security
67
Move Alarm Switch
68
Electrical Considerations
69
Operation and Maintenance
75
Overview
75
Safety Messages
75
Recommended Calibration Tasks
75
Calibration Overview
76
Trimming the Pressure Signal
80
Trimming the Analog Output
81
Chapter 6 Troubleshooting
85
Overview
85
Safety Messages
85
Troubleshooting for 4-20 Ma Output
85
Diagnostic Messages
87
Disassembling the Transmitter
93
Reassemble the Transmitter
95
Service Support
98
Safety Instrumented Systems (SIS) Requirements
99
Identify Rosemount 3051 Safety Certification
99
Installation in Safety Instrumented Systems (SIS) Applications
99
Configuring in Safety Instrumented Systems (SIS) Applications
100
Safety Instrumented Systems (SIS) Operation and Maintenance
101
Inspection
103
Emerson Rosemount 3051 Manual (127 pages)
Transmitter With Foundation fieldbus protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 5.89 MB
Table of Contents
Installation
7
Safety Messages
7
General Considerations
8
Mechanical Considerations
8
Mounting Requirements
15
Process Connections
17
Housing Rotation
19
Panel Mounting
20
Pipe Mounting
20
Mounting Bolts
23
Differential Transmitter
26
Electrical Considerations
30
Hazardous Locations
30
Field Wiring
31
Shield Wire Ground
31
Power Connections
32
Grounding the Transmitter Housing
32
Optional Transient Protection Terminal Block
33
Environmental Considerations
34
Access Requirements
35
Cover Installation
35
Node Address
37
FOUNDATION Fieldbus
37
Integrator Block
38
Operation and Maintenance
45
Disassembly Procedures
45
Remove the Terminal Block
46
Remove the Electronics Board
46
Remove the Sensor Module from the Electronics Housing
47
Reassembly Procedures
48
Attach the Electronics Board
49
Returning Rosemount Products and Materials
51
Performance Specifications
55
Specifications and Reference Data
55
Reference Accuracy
56
Static Pressure
57
Mounting Position Effects
57
Functional Specifications
58
Physical Specifications
62
Standard Configuration
64
Output Information
65
Shipping Weights
65
Hazardous Locations Certifications
69
European ATEX Directive Information
71
Block Information
95
Transducer Block
95
Parameters and Descriptions
96
Troubleshooting
100
Resource Block
101
Block Errors
106
Alarm Detection
108
Status Handling
108
Lcd Block
120
Emerson Rosemount 3051 Reference Manual (94 pages)
Pressure Transmitter with PROFIBUS PA Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 3.73 MB
Table of Contents
Table of Contents
3
Chapter 1 Introduction
5
Using this Manual
5
Models Covered
6
Device Revisions
7
Transmitter Overview
7
Product Recycling/Disposal
7
Chapter 2 Configuration
9
Section Overview
9
Safety Messages
9
Hazardous Locations Certifications
9
Configuration Guidelines
9
Basic Setup Tasks
11
Detailed Setup Tasks
13
Chapter 3 Hardware Installation
21
Section Overview
21
Safety Messages
21
Considerations
21
Installation Procedures
22
Rosemount 305, 306, and 304 Manifolds
35
Liquid Level Measurement
46
Chapter 4 Electrical Installation
51
Section Overview
51
Safety Messages
51
LCD Display
52
LCD Display with Local Operator Interface (LOI)
52
Configure Security and Simulation
52
Electrical Considerations
53
Chapter 5 Calibration
61
Section Overview
61
Safety Messages
61
Calibration Overview
61
Determining Calibration Frequency
62
Zero Trim
63
Sensor Trim
64
Recall Factory Trim
65
Compensating for Line Pressure
66
Chapter 6 Troubleshooting
69
Section Overview
69
Safety Messages
69
Service Support
69
Diagnostics and Recommended Action
70
Plantweb ™ and NE107 Diagnostics
73
Alert Messages and Fail Safe Type Selection
74
Disassembly Procedures
75
Reassembly Procedures
77
Appendix A Reference Data
81
Product Certifications
81
Ordering Information, Specifications, and Drawings
81
Emerson Rosemount 3051 Quick Start Manual (53 pages)
Pressure Transmitter and Flow Meters with FOUNDATION Fieldbus Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 2.86 MB
Table of Contents
About this Guide
3
Safety Messages
3
System Readiness
5
Confirm Correct Device Driver
5
Transmitter Installation
7
Mounting Options
7
Bolting Considerations
11
O-Rings with Flange Adapters
13
Consider Housing Rotation
16
Set the Switches
17
Connect Wiring and Power up
18
Signal Wiring Grounding
20
Power Supply
20
Power Conditioner
20
Shield Wire Ground
21
Signal Termination
21
Locating Devices
21
Before You Begin
23
AI Block Configuration
24
Zero Trim the Transmitter
29
Product Certifications
31
European Directive Information
31
Ordinary Location Certification
31
Republic of Korea
42
Technical Regulations Customs Union (EAC)
43
Conduit Plugs and Adapters
44
Additional Certifications
45
Declaration of Conformity
46
Table of Contents
53
Emerson Rosemount 3051 Quick Start Manual (52 pages)
Pressure Transmitter with FOUNDATION Fieldbus Protocol
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 2.94 MB
Table of Contents
System Readiness
3
Confirm Correct Device Driver
3
Transmitter Installation
5
Mount the Transmitter
5
Bolting Considerations
9
Consider Housing Rotation
13
Set the Switches
14
Wire, Ground, and Power up
15
Power Supply
17
Power Conditioner
17
Signal Termination
18
Locating Devices
18
AI Block Configuration
21
Zero Trim the Transmitter
26
Product Certifications
27
European Directive Information
27
Ordinary Location Certification
27
Republic of Korea
40
Technical Regulations Customs Union (EAC)
40
Conduit Plugs and Adapters
41
Additional Certifications
42
EU Declaration of Conformity
44
Emerson Rosemount 3051 Quick Start Manual (56 pages)
Pressure Transmitter and Flow Meter
Brand:
Emerson
| Category:
Transmitter
| Size: 2.92 MB
Table of Contents
Table of Contents
3
System Readiness
5
Mounting the Transmitter
7
Tagging
13
Consider Housing Rotation
14
Set the Switches
15
Wire, Ground, and Power up
17
Configure
20
Zero Trim the Transmitter
28
Product Certifications
29
Emerson Rosemount 3051 Quick Start Manual (52 pages)
Pressure Transmitter, Flow Meter
Brand:
Emerson
| Category:
Transmitter
| Size: 5.77 MB
Table of Contents
Table of Contents
2
About this Guide
3
Mounting the Transmitter
5
Rotate Housing
13
Set the Switches
14
Connect the Wiring and Power up
16
Verify Configuration Parameters
21
Trimming the Transmitter
25
Safety Instrumented Systems (SIS)
27
Product Certifications
28
Emerson Rosemount 3051 Operating Instructions Manual (52 pages)
Pressure Transmitter
Brand:
Emerson
| Category:
Transmitter
| Size: 5.86 MB
Table of Contents
Table of Contents
2
About this Guide
3
Mounting the Transmitter
5
Rotate Housing
13
Set the Switches
14
Connect the Wiring and Power up
16
Verify Configuration Parameters
21
Trimming the Transmitter
25
Safety Instrumented Systems (SIS)
27
Product Certifications
28
Emerson Rosemount 3051 Quick Start Manual (52 pages)
Pressure Transmitter, Flow Meter with 4-20 mA HART and 1-5 Vdc Low Power Protocol
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 3.55 MB
Table of Contents
Table of Contents
2
About this Guide
3
Mount the Transmitter
5
Housing Rotation
12
Set the Jumpers
13
Connect the Wiring and Power up
14
Verify Configuration
18
Trim the Transmitter
22
Safety Instrumented Systems (SIS)
24
Product Certifications
28
Emerson Rosemount 3051 Quick Start Manual (48 pages)
Pressure Transmitter
Brand:
Emerson
| Category:
Transmitter
| Size: 5.69 MB
Table of Contents
Table of Contents
2
About this Guide
3
System Readiness
5
Transmitter Installation
7
Safety Instrumented Systems Installation
23
Product Certifications
24
Emerson Rosemount 3051 Quick Start Manual (36 pages)
Flowmeters / Pressure Transmitters
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 5.01 MB
Table of Contents
Table of Contents
2
System Readiness
3
Transmitter Installation
4
Mount the Transmitter
4
Tagging
9
Consider Housing Rotation
10
Set the Switches
10
Wire, Ground, and Power up
11
Configure
13
Zero Trim the Transmitter
19
Product Certifications
20
Emerson Rosemount 3051 Quick Start Manual (34 pages)
Pressure Transmitters and flowmeters with 4-20 mA HART and 1-5 Vdc Low Power Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 5.4 MB
Table of Contents
Table of Contents
2
Mount the Transmitter
3
Consider Housing Rotation
7
Set the Jumpers
8
Connect the Wiring and Power up
8
September
9
Verify Configuration
11
Trim the Transmitter
14
Safety Instrumented Systems (SIS)
15
Visual Inspection
17
Specifications
17
Product Certifications
18
Emerson Rosemount 3051 Quick Start Manual (30 pages)
Pressure Transmitter; 3051CF Series Flowmeter
Brand:
Emerson
| Category:
Transmitter
| Size: 2.81 MB
Table of Contents
Table of Contents
2
Mount the
3
Transmitter
3
Consider Housing Rotation
7
Set Jumpers and Switches
7
Connect Wiring and Power up
8
Basic Configuration
10
Trim the Transmitter
13
Product Certifications
14
Emerson Rosemount 3051 Quick Start Manual (28 pages)
Pressure Transmitter and DP Flow Meters with WirelessHART Protocol
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 2.51 MB
Table of Contents
Wireless Considerations
5
Transmitter Installation
6
Mounting the Transmitter
6
Mounting Options
7
Consider Housing Rotation
15
Troubleshooting
16
Product Certifications
17
Declaration of Conformity
23
Emerson Rosemount 3051 Quick Start Manual (23 pages)
Pressure Transmitter and Flowmeters
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 2.86 MB
Table of Contents
Table of Contents
2
Wireless Considerations
3
Transmitter Installation
4
Mount the Transmitter
4
Consider Housing Rotation
8
Connect the Power Module
8
Trim the Transmitter
9
Verify Transmitter Configuration
10
Troubleshooting
13
Product Certifications
14
Emerson Rosemount 3051 Quick Start Manual (28 pages)
Pressure Transmitter and DP Flow Meters with WirelessHART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 2.81 MB
Table of Contents
Wireless Considerations
3
Transmitter Installation
4
Troubleshooting
16
Product Certifications
17
Emerson Rosemount 3051 Quick Start Manual (28 pages)
Pressure Transmitter, DP Flow Meter
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 3.78 MB
Table of Contents
Wireless Considerations
3
Transmitter Installation
4
Troubleshooting
18
Product Certifications
19
Emerson Rosemount 3051 Quick Installation Manual (17 pages)
Pressure Transmitter with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 2.2 MB
Table of Contents
Important Notice
2
Consider Housing Rotation
5
Set the Jumpers
5
Power Supply
7
Step 5: Configure the Transmitter
8
Step 6: Trim the Transmitter
10
Zero Trim
10
Product Certifications
11
Approved Manufacturing Locations
11
European Pressure Equipment Directive (PED) (97/23/EC)
11
Ordinary Location Certification for Factory Mutual
11
Hazardous Locations Certifications
12
North American Certifications
12
European Certifications
13
Japanese Certifications
14
Emerson Rosemount 3051 Quick Start Manual (22 pages)
Pressure Transmitter and DP Flowmeters With WirelessHART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 3.71 MB
Table of Contents
Table of Contents
2
Wireless Considerations
3
Mount the Transmitter
4
Connect the Power Module
8
Trim the Transmitter
8
Verify Transmitter Configuration
10
Troubleshooting
13
Product Certifications
14
Emerson Rosemount 3051 Quick Installation Manual (20 pages)
Pressure Transmitter with FOUNDATION Fieldbus / Flowmeter Transmitter with FOUNDATION Fieldbus
Brand:
Emerson
| Category:
Transmitter
| Size: 2.53 MB
Emerson Rosemount 3051 Manual (9 pages)
Sensor Module Replacement
Brand:
Emerson
| Category:
Transmitter
| Size: 0.37 MB
Table of Contents
Safety Messages
1
Before You Disassemble the Transmitter
2
Disassembly Procedures
2
Remove the Electronics Board
3
Remove the Sensor Module from the Electronics Housing
4
Reassembly Procedures
5
Attach the Electronics Board
6
Reassemble the Process Sensor Body
7
Install the Drain/Vent Valve
8
Advertisement
Related Products
Emerson Rosemount 3051S Series
Emerson Rosemount 3051SF Series
Emerson Rosemount 3051N
Emerson Rosemount MultiVariable 3051SMV
Emerson Rosemount 3051P
Emerson Rosemount MultiVariable 3051SFA
Emerson Rosemount MultiVariable 3051SFC
Emerson Rosemount MultiVariable 3051SFP