Motorola AP-7131 Installation Manual page 20

Hide thumbs Also See for AP-7131:
Table of Contents

Advertisement

16
AP-7131 Access Point: Installation Guide
CAUTION
The mounting hardware required to install the AP-7131 above a ceiling consists of:
• Light pipe
• Badge for light pipe
• Decal for badge
• Safety wire (strongly recommended)
• Security cable (optional)
To install the AP-7131 above a ceiling:
NOTE
1. If possible, remove the adjacent ceiling tile from its frame and place it aside.
2. If required, install a safety wire, between 1.5mm (.06in.) and 2.5mm (.10in.) in diameter, in
the ceiling space.
3. If required, install and attach a security cable to the AP-7131's lock port.
4. Mark a point on the finished side of the tile where the light pipe is to be located.
5. Create a light pipe path hole in the target position on the ceiling tile.
6. Use a drill to make a hole in the tile the approximate size of the AP-7131 LED light pipe.
CAUTION
7. Remove the light pipe's rubber stopper (from the AP-7131) before installing the light pipe.
Motorola does not recommend mounting the AP-7131 directly to any
suspended ceiling tile with a thickness less than 12.7mm (0.5in.) or a
suspended ceiling tile with an unsupported span greater than 660mm
(26in.). Motorola strongly recommends fitting the AP-7131 with a
safety wire suitable for supporting the weight of the device. The
safety wire should be a standard ceiling suspension cable or
equivalent steel wire between 1.59mm (.062in.) and 2.5mm (.10in.)
in diameter.
Remove the access point's facade and antennas before installing in an
above the ceiling orientation. The AP-7131 is not certified for an above
the ceiling installation with its accessories installed.
Motorola recommends care be taken not to damage the finished
surface of the ceiling tile when creating the light pipe hole and
installing the light pipe.

Advertisement