Ecobee SMART THERMOSTAT Installation Manual

Ecobee SMART THERMOSTAT Installation Manual

Hide thumbs Also See for SMART THERMOSTAT:

Advertisement

©2010 ecobee
333 Adelaide Street West | 6th Floor
Toronto | Ontario | M5V 1R5 | Canada
toll free 1.877.932.6233
www.ecobee.com
IM-STAT-106-R5
SMART THERMOSTAT

Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMART THERMOSTAT and is the answer not in the manual?

Questions and answers

Dean
March 25, 2025

Wires not locking in

1 comments:
Mr. Anderson
March 25, 2025

The wires may not be locking in on the Ecobee Smart Thermostat because they are not inserted into the correct side of the terminal blocks. Ensure that the wires are inserted into the side, not the front. Additionally, pressing the terminal block levers can help insert the wires more easily. Tug gently on the wires to confirm they are securely connected.

This answer is automatically generated

Summary of Contents for Ecobee SMART THERMOSTAT

  • Page 1: Installation Manual

    ©2010 ecobee 333 Adelaide Street West | 6th Floor Toronto | Ontario | M5V 1R5 | Canada toll free 1.877.932.6233 SMART THERMOSTAT www.ecobee.com Installation Manual IM-STAT-106-R5...
  • Page 2: Table Of Contents

    CONTENTS Getting Started Welcome HVAC System Compatibility Information Specifications Installing the ecobee Smart Thermostat Wiring Diagrams Equipment Interface Status LED Navigating the Smart Thermostat Configuring the Installer Settings Configuring the Reminder Alerts Performing a Hardware Reset Warranty...
  • Page 3: Getting Started

    GETTING STARTED Welcome Thank you for supporting ecobee, the Smart Thermostat that provides your customers with freedom and flexibility in managing their home environment. The ecobee Smart Thermostat has been designed in partnership with HVAC contractors to ensure the installation process is simple and efficient. This step-by-step Installation Manual will walk you through all aspects of the installation.
  • Page 4: Hvac System Compatibility Information

    The ecobee Smart Thermostat consists of two parts Central humidifier (see images below): Central dehumidifier 1. A Smart Thermostat to be mounted on the Heat Recovery Ventilator (HRV) homeowner’s wall. Energy Recovery Ventilator (ERV) 2. An Equipment Interface Module This should be...
  • Page 5: Specifications

    3rd accessory relay 30V AC Dimensions ACC3r 3rd accessory relay return 30V AC Smart Thermostat: 5.5”W x 3.25”H x 1”D (139.5mm H x IN1 + Input 1 + Dry contact only Dry contact only 82.5mm W x 25mm D) IN1-...
  • Page 6: Installing The Ecobee Smart Thermostat

    INSTAllING THE SMART THERMOSTAT There are five steps to installing the ecobee Smart Thermostat Step 1: Install the Equipment Interface. Step 2: Wire the Equipment Interface. Step 3: Install the Smart Thermostat. Step 4: Connect the Smart Thermostat to the Equipment Interface.
  • Page 7: Wiring Diagrams

    Diagram indicates 24V humidi er terminal. If your furnace control board does not have this, you must use a 110V/24V step down transformer. from RH / RC to ACC1, ACC2, ACC3 for a 24V feed. Installing The Smart Thermostat Installing The Smart Thermostat...
  • Page 8 Diagram indicates 24V humidi er terminal. If your furnace control board does not have this, you must use a 110V/24V step down transformer. from RH / RC to ACC1, ACC2, ACC3 for a 24V feed. Installing The Smart Thermostat Installing The Smart Thermostat...
  • Page 9 Non Powered Accessories will require a jumper from RH | RC to ACC1, ACC2, ACC3 for a 24V feed. indicates a jumper. Non-powered accessories require a jumper from RH / RC to ACC1, ACC2, ACC3 for a 24V feed. Remove factory installed jumper Installing The Smart Thermostat Installing The Smart Thermostat...
  • Page 10: Installing The Smart Thermostat

    Follow these steps to connect the Smart Thermostat to the Equipment Interface: 1. Connect the wires between the Smart Thermostat and Equipment Interface as shown below.
  • Page 11: Equipment Interface Status Led

    Equipment Interface Status LED 3. Attach the front cover of the Smart Thermostat to the backplate. Ensure the four pins on the circuit board mate The Equipment Interface has four LEDs to display the with the terminal block on the backplate as shown below.
  • Page 12: Navigating The Smart Thermostat

    (such as a furnace, air conditioner, The Smart Thermostat uses touch screen technology, so it’s humidifier, dehumidifier or ventilator) that are connected From the Home easy to navigate – just tap the icons, buttons and lists.
  • Page 13 65°F (18.3°C) or can be completly disable. You will need an Staging Method of Operation Internet connection for this feature to operate properly. The ecobee Smart Thermostat uses a unique method Allow Heat pump/Auxiliary Heat to run simultaneously for staging for multi-stage heating or cooling. It uses...
  • Page 14 Ventilator Max is engaged Max Outdoor Temperature Allows you to set the maximum outdoor temperature threshold. Above this level, the auxiliary heat will not be activated. Instead, the heat pump will maintain the set point. Configuring The Smart Thermostat Configuring The Smart Thermostat...
  • Page 15 Website address. Test Equipment If you are a registered ecobee contractor, you will have access to your Contractor portal. In this portal, This section allows you to manually turn on and off the you can enter the serial number of each ecobee various equipment connected to the Equipment Interface, Smart Thermostat you install.
  • Page 16: Configuring The Reminder Alerts

    Reset All Setting Furnace Filter The Furnace Air Filter reminder generates an alert for Selecting this option will reset the entire Smart Thermostat cleaning or changing the furnace air filter. system back to the original factory default settings. Select this item to turn the reminder on or off, and to select Performing a Hardware reset the reminder interval (in hours or calendar months).
  • Page 17 Used if this input is programmed to In a heat pump with auxiliary heat configuration, you can generate an alert. program the Smart Thermostat to generate an alert if the auxiliary heat is called for when the outdoor temperature Input 2...
  • Page 18: Warranty

    This warranty does not cover removal or reinstallation costs and shall not apply if the damages were found to be ecobee warrants that for a period of three (3) years from caused by something other than defects in materials or the date of purchase by the consumer (“Customer”),...