Feature Manual References
1.9.2 ICD Group Features—Group Call Distribution
Options—Wrap-up Timer based on
Selects whether the ICD Group member wrap-up timer or extension wrap-up timer is used.
If Extension is selected here, Wrap-up Timer on 2.9.12 [3-5-4] Incoming Call Distribution
Group—Member becomes unavailable. If ICD Group Member is selected, Wrap-up Timer on
2.10.1 [4-1-1] Wired Extension—Extension Settings and 2.10.10 [4-2-1] Portable Station—
Extension Settings become unavailable.
Default
Extension
Value Range
Extension: The timer is activated after all calls to or from the extension, including a retrieved call on
hold.
ICD Group Member: The timer is only activated after calls to the extension through an ICD Group.
Maintenance Console Location
2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous
Programming Manual References
2.9.12 [3-5-4] Incoming Call Distribution Group—Member—Wrap-up Timer
2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 8—Wrap-up Timer
2.10.10 [4-2-1] Portable Station—Extension Settings—Option 8—Wrap-up Timer
Feature Manual References
1.9.3 ICD Group Features—Log-in/Log-out
2.9.12 [3-5-4] Incoming Call Distribution Group—Member
Each incoming call distribution group can have a maximum of 32 (with the KX-TDA50/KX-TDA100/
KX-TDA200) or 128 (with the KX-TDA600) members (extensions) assigned to it, and each member
can have its own delayed ringing and Wrap-up time settings. An extension can be a member of
multiple incoming call distribution groups. An ICD Group can also contain cellular phones, and
network ICD groups (ICD groups at other PBXs in a network) using virtual PS (see "1.19.2 Virtual
PS" in the Feature Manual). The forward destination assigned to a virtual PS (e.g., a cellular phone)
can act as a member of an ICD group. Select the desired ICD group (1–128) from the ICD Group No.
list.
To assign members to the group, enter directly or click Extension Number Setting (see 2.1.6
Extension Number Setting). To copy the members to another group, click Member List Copy,
select the group, and click OK.
Note
This screen is only displayed by default when accessing the Maintenance Console in
Administrator level.
2.9 [3] Group