Panasonic KX-TDA50 Programming Manual page 189

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Gateway Address [Common Settings]
Displays the default gateway address of the network for IP-PTs (reference only).
To change the value displayed here, click Common Settings, and set the desired value for Gateway
Address.
Default
0.0.0.0
Value Range
1.0.0.0–223.255.255.255
Maintenance Console Location
2.7.22 [1-1] Slot—IP-Extension Card Property
Programming Manual References
2.7.23 [1-1] Slot—IP-Extension Card Property—Common Settings
Feature Manual References
1.9.15 IP-PT (IP Proprietary Telephone)
Keep Alive Time Out
Specifies the length of time that the PBX will continue to consider an IP-PT to be active even if it
receives no transmissions from that IP-PT. The PBX constantly confirms the status of IP-PTs. If no
communications are received from an IP-PT for the duration specified here, the PBX considers the
IP-PT to be unreachable, and sets the port status to Fault.
During operation, set between 10 s and 60 s. Settings over 60 s, and Disable, are used for debugging
purposes, and IP-PTs cannot be guaranteed to function normally in these circumstances. Do not use
debugging settings unless instructed to do so.
Default
10 s
Value Range
Disable, 10–120 s
Maintenance Console Location
2.7.22 [1-1] Slot—IP-Extension Card Property
Programming Manual References
None
Feature Manual References
1.9.15 IP-PT (IP Proprietary Telephone)
Echo Canceller Ability
Specifies the echo canceler ability time.
2.7 [1] Configuration
PC Programming Manual
189

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda100Kx-tda200Kx-tda600

Table of Contents